English
Language : 

BC384R480T065VM-00 Datasheet, PDF (3/10 Pages) Vicor Corporation – BCM Array™
SPECIFICATIONS
1.0 ELECTRICAL CHARACTERISTICS (CONT.)
Specifications apply over all line and load conditions unless otherwise noted; Boldface specifications apply over the
temperature range of -40°C < TC < 100°C (T-Grade); All other specifications are at TC = 25ºC unless otherwise noted
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN
TYP
MAX UNIT
PROTECTION
Negative going OVLO
Positive going OVLO
Negative going UVLO
Positive going UVLO
Output Overcurrent Trip
Short Circuit Protection
Trip Current
Short Circuit Protection
Response Time
Thermal Shutdown
Junction setpoint
GENERAL SPECIFICATION
Isolation Voltage (Hi-Pot)
Working Voltage (IN – OUT)
Isolation Capacitance
Isolation Resistance
MTBF
Agency Approvals/Standards
VIN_OVLO-
VIN_OVLO+
VIN_UVLO-
VIN_UVLO+
IOCP
ISCP
VIN = 384 V, 25°C
TSCP
TJ_OTP
VHIPOT
VWORKING
CIN_OUT
RIN_OUT
Unpowered unit
MIL HDBK 217F, 25° C, GB
cTUVus (Pending Approvals)
CE Mark
400
420
430
V
420
430
440
V
270
285
304
V
290
310
330
V
18
22
28
A
28
A
1.2
µs
125
130
135
°C
4242
500
660
5
2.1
V
500
V
800
pF
MΩ
Mhrs
VI BRICK BCM Array
BC384R480T065VM-00
vicorpower.com
Rev. 1.1
Page 3 of 10