BCM3814X60E10A5YZZ Datasheet, PDF (28/39 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
Supported Commands Transaction Type
A direct communication to the BCM internal µC and a simulated
communication to non-PMBus™ devices is enabled by a page
command. Supported command access privileges with a pre-
selected PAGE are defined in the following table. Deviation from
this table generates a communication error in
STATUS_CML register.
Command
PAGE
OPERATION
ON_OFF_CONFIG
CLEAR_FAULTS
CAPABILITY
OT_FAULT_LIMIT
OT_WARN_LIMIT
VIN_OV_FAULT_LIMIT
VIN_OV_WARN_LIMIT
IIN_OC_FAULT_LIMIT
IIN_OC_WARN_LIMIT
TON_DELAY
STATUS_BYTE
STATUS_WORD
STATUS_IOUT
STATUS_INPUT
STATUS_TEMPERATURE
STATUS_CML
STATUS_MFR_SPECIFIC
READ_VIN
READ_IIN
READ_VOUT
READ_IOUT
READ_TEMPERATURE_1
READ_POUT
PMBUS_REVISION
MFR_ID
MFR_MODEL
MFR_REVISION
MFR_LOCATION
MFR_DATE
MFR_SERIAL
MFR_VIN_MIN
MFR_VIN_MAX
MFR_VOUT_MIN
MFR_VOUT_MAX
MFR_IOUT_MAX
MFR_POUT_MAX
BCM_EN_POLARITY
READ_K_FACTOR
READ_BCM_ROUT
SET_ALL_THRESHOLDS
DISABLE_FAULT
Code
00h
01h
02h
03h
19h
4Fh
51h
55h
57h
5Bh
5Dh
60h
78h
79h
7Bh
7Ch
7Dh
7Eh
80h
88h
89h
8Bh
8Ch
8Dh
96h
98h
99h
9Ah
9Bh
9Ch
9Dh
9Eh
A0h
A1h
A4h
A5h
A6h
A7h
D0h
D1h
D4h
D5h
D7h
PAGE Data Byte
Access Type
00h
01h
R/W
R/W
R
R/W
R
W
W
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R/W
R
R/W
R
R/W
R/W
R
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W
R
R
R/W
R/W
BCM® in a VIA Package
Page 28 of 39
Rev 1.4
09/2016
BCM3814x60E10A5yzz
Page Command (00h)
The page command data byte of 00h prior to a command call will
address the internal µC specific data and a page data byte of FFh
would broadcast to all of the connected BCMs. The value of the
Data Byte corresponds to the pin name trailing number with the
exception of 00h and FFh.
Data Byte
00h
01h
µC
BCM
Description
OPERATION Command (01h)
The Operation command can be used to turn on and off the
connected BCM. Note that the host OPERATION command will not
enable the BCM if the BCM EN pin is disabled in hardware with
respect to the pre‐set pin polarity. Only with the EN pin active, will
the OPERATION command provide ON/OFF control.
If synchronous startup is required in the system, it is recommended
to use the command from host PMBus in order to achieve
simultaneous array startup.
Unit is On when asserted (default)
Reserved
76543210
10000000b
This command accepts only two data values: 00h and 80h. If any
other value is sent the command will be rejected and a CML Data
error will result.