English
Language : 

V110B24C200BL_16 Datasheet, PDF (2/14 Pages) Vicor Corporation – DC-DC Converter Module
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Operating input voltage
66
110
154
VDC
Input surge withstand
250
VDC
Undervoltage turn-on
64
65.4
VDC
Undervoltage turn-off
54
56
VDC
Overvoltage turn-off/on
155.5
161.7
169.4
VDC
Disabled input current
1.3
mA
Notes
Per EN50155 and GBT-25119
<100ms
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Output voltage setpoint
Line regulation
±0.02
±1
±0.20
% VOUT nom.
%
Temperature regulation
±0.002
±0.005
% / °C
Power sharing accuracy
±2
±5
%
Programming range
10
110
%
+Out to –Out, +Sense to –Out — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
VDC
–0.5 to 7.0
VDC
–0.5 to 10.9
VDC
–0.5 to 16.1
VDC
–0.5 to 20.0
VDC
–0.5 to 31.7
VDC
–0.5 to 36.9
VDC
–0.5 to 47.4
VDC
–0.5 to 62.9
VDC
Notes
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
THERMAL RESISTANCE AND CAPACITY
Parameter
Min
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
Typ
Max
0.16
0.14
8.0
1.9
83
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Mini Family
Page 2 of 14
Rev 3.4
10/2016
vicorpower.com
800 927.9474