PRM48JH480x250A00
High Level Functional State Diagram
Conditions that cause state transitions are shown along arrows. Sub-sequence activities listed inside the state bubbles.
Application of
Vin
VIN > UVLO+
STANDBY SEQUENCE
ENABLE: 10uA to LOW
tOFF expired
ENABLE: 90uA to HIGH
Powertrain Stopped
Fault
Auto-
recovery
ENABLE rising edge
ENABLE falling edge,
Output OVP,
or OTP detected
Input OVLO or UVLO,
Output UVP,
or UTP detected
STARTUP SEQUENCE
tON expired
ENABLE: 1.8mA to HIGH
VC Pulse
REF_EN active
Adaptive loop and trim modes latched
RS mode latched at first ENABLE
after Vin applied only
Powertrain Active
tSTARTUP_SEQ
expired
FAULT SEQUENCE
ENABLE pulsed: 25mA to
LOW
Powertrain Stopped
ENABLE falling edge,
Output OVP or
OTP detected
Input OVLO or UVLO,
Output UVP,
or UTP detected
Short Circuit detected
VIN < VIN_DROPOUT_EN-
SUSTAINED
OPERATION
ENABLE: 1.8mA to HIGH
Powertrain Active
tDROPOUT expired or
VIN ≤ VIN_UVLO-_SUPV
LINE DROP-OUT
OPERATION
Powertrain Active
Derated Power
and Current
tDROPOUT timer enabled
t < tDROPOUT and
VIN > VIN_DROPOUT_DIS+
PRMTM Regulator
Page 18 of 44
Rev 1.2
11/2015
vicorpower.com
800 927.9474