English
Language : 

PRM48JH480T250A00 Datasheet, PDF (13/44 Pages) Vicor Corporation – High Efficiency Converter
PRM48JH480x250A00
Signal Specifications (cont.)
Specifications apply over all line and load conditions, TINT = 25ºC and output voltage from 20.0 V to 55.0 V, unless otherwise noted.
Boldface specifications apply over the temperature range of -40ºC < TINT < 125ºC (T-grade).
AL: Adaptive Loop (Adaptive Loop Operation Only)
• Provides Adaptive Loop load line programming in Adaptive Loop Operation
• Internal pullup to VCC_INT through 10 kΩ resistor
• Sampled prior to every start up to detect if Adaptive Loop load line is active or inactive
• Leave open to disable Adaptive Loop load line
• Not used in Remote Sense Operation
Signal Type
State
Attribute
Symbol
Conditions / Notes
AL Enable Threshold
VAL_EN
Pull below this value during start up
to enable AL load line
AL Disable Threshold
VAL_DIS
Pull above this value during start up
to disable AL load line
Start up Minimum AL Disable
Minimum AL resistance required
RAL_DIS_MIN
Resistance
to disable AL load line
AL Capacitance
(External)
CAL_EXT
Analog Input
AL Sample Delay
Internally generated
VCC
tENABLE_AL
VCC_INT
From ENABLE high to AL sampled
Internal Pullup
Resistance to VCC_INT
RAL_INT 0.5% tolerance resistor
Normal
Operation
AL Pin Analog Range
AL Gain
AL Load Line Accuracy
VAL_RANGE
GAL
%ACC_LL_AL
Positive correction slope, VT inactive
Full load slope accuracy exclusive
of external resistor tolerance
AL Load Line Resolution LLAL_RES
Maximum Output
Maximum increase from no
VOUT_AL_MAX
Referred Compensation
load setpoint, VOUT ≤ 55.0 V
AL Latency
AL Bandwidth
tAL_LAT
BWAL
-3dB point
Min
3.10
10
100
3.20
9.83
0
65
Typ
150
3.28
10.00
1.0
0.5
3
130
1.2
Max
3.20
100
200
3.36
10.18
3.10
2.0
5
260
Unit
V
V
MΩ
pF
µs
V
kΩ
V
Ω/V
%
mΩ
V
µs
kHz
PRMTM Regulator
Page 13 of 44
Rev 1.2
11/2015
vicorpower.com
800 927.9474