English
Language : 

BCM6123XD1E5117YZZ Datasheet, PDF (18/30 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM6123xD1E5117yzz
Application Characteristics
Product is mounted and temperature controlled via top side cold plate, unless otherwise noted. All data presented in this section are collected data from
primary sourced units processing power in forward direction.See associated figures for general trend data.
15
14
13
12
11
10
9
8
7
6
5
4
3
260 275 290 305 320 335 350 365 380 395 410
Input Voltage (V)
T : TOP SURFACE CASE
- 40°C
25°C
90°C
Figure 4 — No load power dissipation vs. VPRI_DC
98.0
97.5
97.0
96.5
96.0
-40
-20
0
20
40
60
80
100
Case Temperature (°C)
VPRI:
260V
380V
410V
Figure 5 — Full load efficiency vs. temperature; VPRI_DC
98
96
94
92
90
88
86
84
82
80
0.0 1.8 3.5 5.3 7.0 8.8 10.5 12.3 14.0 15.8 17.5
Secondary Output Current (A)
VPRI :
260V
380V
410V
Figure 6 — Efficiency at TCASE = -40°C
45
40
35
30
25
20
15
10
5
0
0.0 1.8 3.5 5.3 7.0 8.8 10.5 12.3 14.0 15.8 17.5
Secondary Output Current (A)
VPRI :
260V
380V
410V
Figure 7 — Power dissipation at TCASE = -40°C
98
96
94
92
90
88
86
84
82
80
0.0 1.8 3.5 5.3 7.0 8.8 10.5 12.3 14.0 15.8 17.5
Secondary Output Current (A)
VPRI :
260V
380V
410V
Figure 8 — Efficiency at TCASE = 25°C
BCM® Bus Converter
Page 18 of 30
Rev 1.0
03/2017
45
40
35
30
25
20
15
10
5
0
0.0 1.8 3.5 5.3 7.0 8.8 10.5 12.3 14.0 15.8 17.5
Secondary Output Current (A)
VPRI :
260V
380V
410V
Figure 9 — Power dissipation at TCASE = 25°C
vicorpower.com
800 927.9474