English
Language : 

BCM6123XD1E5117YZZ Datasheet, PDF (10/30 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM6123xD1E5117yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TINTERNAL ≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Secondary Overvoltage
Lockout Threshold
Secondary Overvoltage
Lockout Response Time
Secondary Undervoltage
Lockout Threshold
Secondary Undervoltage
Lockout Response Time
Protection SECONDARY to PRIMARY (Reverse Direction)
VSEC_OVLO+ Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
52.5
54.5
56.5
V
tPRI_OVLO
100
µs
VSEC_UVLO- Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
14
15
16
V
tSEC_UVLO
100
µs
Primary Undervoltage
Lockout Threshold
Applies only to reversilbe products in forward and in
VPRI_UVLO-_R
reverse direction; IPRI_DC ≤ 20% while VPRI_UVLO-_R
< VPRI_DC < VPRI_MIN
110
120
130
V
Primary Undervoltage
Recovery Threshold
VPRI_UVLO+_R
Applies only to reversilbe products in forward and in
reverse direction
120
130
150
V
Primary Undervoltage
Lockout Hysteresis
VPRI_UVLO_HYST_R
Applies only to reversilbe products in forward and in
reverse direction
10
V
Primary Output Overcurrent
Trip Threshold
IPRI_OUT_OCP Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
2.25
2.9
5
A
Primary Output Overcurrent
Response Time Constant
tPRI_OUT_OCP Effective internal RC filter
3.6
ms
Primary Short Circuit Protection
Trip Threshold
IPRI_SCP
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
3.75
A
Primary Short Circuit Protection
Response Time
tPRI_SCP
1
µs
BCM® Bus Converter
Page 10 of 30
Rev 1.0
03/2017
vicorpower.com
800 927.9474