PI2127 Datasheet, PDF (16/19 Pages) Vicor Corporation – 60 Volt, 12 Amp Full-Function Active ORing Solution | |||
|
◁ |
ï
Figure 24: PI2127 in high side +48V application, VC
is biased through constant current circuit.
Layout Recommendation:
Use the following general guidelines when designing
printed circuit boards. An example of the typical land
pattern for the PI2127 is shown in
Figure 25:
⢠Make sure to have a solid ground (return) plane to
reduce circuit parasitic.
⢠Connect all S pads together with a wide trace to
reduce trace parasitics to accommodate the high
current input, and also connect all D pads
together with a wide trace to accommodate the
high current output.
⢠Connect the SP pin to the S pins and connect the
SN pin to D pins as shown in Figure 25.
⢠Use 1oz of copper or thicker if possible to reduce
trace resistance and reduce power dissipation.
Figure 25: PI2127 layout recommendation
Picor Corporation ⢠picorpower.com
PI2127
Rev 1.3
Page 16 of 19
|
▷ |