English
Language : 

BCM380P475T1K2A30 Datasheet, PDF (13/25 Pages) Vicor Corporation – Fixed Ratio DC-DC Converter
BCM380x475y1K2A3z
High Level Functional State Diagram
Conditions that cause state transitions are shown along arrows. Sub-sequence activities listed inside the state bubbles.
Application
of input voltage to VPRI_DC
V < V < V μC_ACTIVE
PRI_DC
PRI_UVLO+
STANDBY SEQUENCE
TM Low
EN High
VAUX Low
Powertrain Stopped
Fault
Auto-
recovery
V > V PRI_DC
PRI_UVLO+
STARTUP SEQUENCE
TM Low
EN High
VAUX Low
ENABLE falling edge,
or OTP detected
Powertrain Stopped
Input OVLO or UVLO,
Output OCP,
or UTP detected
tPRI_UVLO+_DELAY
expired
ONE TIME DELAY
INITIAL STARTUP
FAULT
SEQUENCE
TM Low
EN High
VAUX Low
Powertrain Stopped
ENABLE falling edge,
or OTP detected
Input OVLO or UVLO,
Output OCP,
or UTP detected
Short Circuit detected
SUSTAINED
OPERATION
TM PWM
EN High
VAUX High
Powertrain Active
BCM® Bus Converter
Page 13 of 25
Rev 1.7
07/2015
vicorpower.com
800 927.9474