English
Language : 

CD-700_09 Datasheet, PDF (9/12 Pages) Vectron International, Inc – Complete VCXO Based Phase Lock Loop
Table 5. Environmental Compliance
Parameter
PreHeat Time
Ramp Up
Time Above 217 oC
Time To Peak Temperature
Time At 260 oC
Ramp Down
Symbol
t
S
R
UP
t
L
t
AMP-B
t
P
R
DN
The device has been qualified to meet the JEDEC
standard for Pb-Free assembly. The temperatures and
time intervals listed are based on the Pb-Free small
body requirements. The temperatures refer to the
topside of the package, measured on the package
body surface. The CD-700 device is hermetically sealed
so an aqueous wash is not an issue.
Value
60 sec Min, 180 sec Max
3 0C/sec Max
60 sec Min, 150 sec Max
480 sec Max
20 sec Min, 40 sec Max
6 0C/sec Max
Tape and Reel
Figure 12. Suggested IR Profile
Table 6. Tape and Reel Information
Tape Dimensions (mm)
A
B
C
D
E
16
7.5
1.5
4
8
Figure 13. Tape and Reel
Reel Dimensions (mm)
F
G
H
I
J
1.5
20.2
13
50
6
K
L #/Reel
16.4 178 200
Page 9 of 12
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Rev: 30Mar2009