English
Language : 

VC-708_11 Datasheet, PDF (6/7 Pages) Vectron International, Inc – LVPECL, LVDS Crystal Oscillator Data Sheet Ultra Low Phase Noise
Maximum Ratings, Tape & Reel
Absolute Maximum Ratings and Handling Precautions
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional operation is not implied or any other
excess of conditions represented in the operational sections of this data sheet. Exposure to absolute maximum ratings for extended
periods may adversely affect device reliability.
Although ESD protection circuitry has been designed into the VC-708, proper precautions should be taken when handling and mounting,
VI employs a Human Body Model and Charged Device Model for ESD susceptibility testing and design evaluation.
ESD thresholds are dependent on the circuit parameters used to define the model. Although no industry standard has been adopted for
the CDM a standard resistance of 1.5kOhms and capacitance of 100pF is widely used and therefor can be used for comparison purposes.
Table 6. Maximum Ratings
Parameter
Symbol
Rating
Unit
Storage Temperature
Supply Voltage
TSTORE
-50/125
°C
-0.5 to 7.0
V
ESD, Human Body Model
1500
V
ESD, Charged Device Model
1000
V
Table 7. Tape and Reel Information
Tape Dimensions (mm)
W
F
Do
Po
P1
A
Reel Dimensions (mm)
B
C
D
N
W1
W2
#/Reel
16
7.5
1.5
4
8
180
2
13
21
55
17
21
250
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com