English
Language : 

TFS150C1 Datasheet, PDF (5/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 150c1.doc
VI TELEFILTER
Version 1.4
Filter specification
TFS 150C1
30.07.2004
5/5
History
Version Reason of Changes
Name
1.1
Generation of specification according to customer requirements.
Dunzow W.
1.2
Change defenition of insertion loss.
Dr. Wall
Change remark according to temperature dependence and production tolerance.
Remove attenuation requirement at fN ± 910 kHz.
Add selection at f6dB- -500 kHz.
Define frequency range were ultimate rejection of 55 dB is measured.
1.3
Add formula for calculation of temperature dependence of frequency.
Change frequency inversion temperature to 25 °C.
Dr. Wall
1.4
Correct termination impedances.
Correct tape and reel.
Add filter characteristic.
Dr. Wall
Date
11.10.2001.
14.11.2001
24.04.2002
27.07.2004
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is