English
Language : 

TFS150C1 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 150c1.doc
VI TELEFILTER
Version 1.4
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
3800 Ω || -0.7 pF
3800 Ω || -0.7 pF
TFS 150C1
30.07.2004
1/5
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 150C1 is the minimum in the usable signal bandwidth. The maximum attenuation amax in the
usable signal bandwidth is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper ( f6dB+ ) and lower (f6dB-)
frequencies at the 6 dB filter attenuation level relative to the insertion loss ae . The nominal frequency fN is fixed at 150,4 MHz without tolerance. The
usable singnal bandwidth has to be guaranteed also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the
operating temperature range and due to a production tolerance for the centre frequency fc
Data
typ. value
tolerance / limit
Insertion loss
ae
(Reference level)
2,8 dB
max.
5 dB
Nominal frequency
fN
Centre frequency
fC
3 dB bandwidth
BW
-
150,41 MHz
107
kHz
150,4 MHz
-
-
Usable signal band width
-
min. fN±10 kHz
Relative attenuation :
arel
f6dB- - 75 kHz ... f6dB- - 50
kHz
-
f6dB+ + 50 kHz ... f6dB+ + 75
kHz
-
f6dB- - 125 kHz ... f6dB- - 75
kHz
-
f6dB+ + 75 kHz ... f6dB+ +125
kHz
-
f6dB- - 250 kHz ... f6dB- - 125
kHz
-
f6dB+ + 125 kHz ... f6dB+ +250
kHz
-
f6dB- - 500 kHz ... f6dB- - 250
kHz
-
f6dB+ + 250 kHz ... f6dB+ +330
kHz
-
f6dB+ + 330 kHz ... f6dB+ +397
kHz
-
f6dB+ + 397 kHz ... f6dB+ +500
kHz
-
f6dB- - 500 kHz ... f6dB- - 10
MHz
-
f6dB+ + 500 kHz ... f6dB+ + 10
MHz
min. 15 dB
min. 15 dB
min. 20 dB
min. 20 dB
min. 35 dB
min. 35 dB
min. 50 dB
min. 50 dB
min. 40 dB
min. 50 dB
min. 55 dB
min. 55 dB
Operating temperature range
-
- 20 °C ... + 70 °C
Storage temperature range
-
- 30 °C ... + 85 °C
Temperature coefficient of frequency TCf **)
ca. – 0,036 ppm/K²
-
Frequency inversion temperature
T0
25
°C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/ K²) x (T-T0)² x fTo(MHz)
Generated:
Checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.