English
Language : 

C4550_06 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Surface Mount Package Optional
C4550
OCXO
Typical Applications
Base Stations
Test Equipment
Synthesizers
Digital Switching
Previous Vectron Model Numbers
Frequency range
Standard frequencies
Features
Surface Mount Package Optional
Reflow Process Compatible Optional
AT-Cut and SC-Cut Crystal Options
Low Profile Compact Package
4853, 4853S, 4597, 4597S,
4859, 4859S, 4877, 4877S, OCO500, OC-260
10 MHz – 100 MHz
10; 12.8;13; 16.384;20; 32.768MHz; 100Mhz
Frequency stabilities1 [AT Cut Crystal – Standard]
Parameter
Min
Typ
Max.
vs. operating temperature range
-50
+50
(Referenced to +25°C)
-100
+100
-150
+150
-200
+200
Parameter
Min
Typ
Max.
Initial tolerance
-300
vs. supply voltage change
-10
vs. load change
-10
+300
+10
+10
vs. aging /1 day
-2.0
+2.0
vs aging /1 Year
-500
vs. aging / year (following Years)
-250
+500
+250
Warm-up Time
3
Frequency stabilities1 [SC Cut Crystal – Option]
Parameter
Min
Typ
Max.
vs. operating temperature range
-10
+10
(Referenced to +25°C)
-20
+20
-25
+25
-30
+30
Parameter
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging /1 day
vs aging /1 Year
vs. aging / year (following Years)
Min
Typ
Max.
-100
+100
-5.0
+5.0
-5.0
+5.0
-1.0
+1.0
-100
+100
-50
+50
Warm-up Time
3
Units
ppb
ppb
ppb
ppb
Units
ppb
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
0 … +70°C
C508
-20 … +70°C
D107
-40 … +70°C
E157
-40 … +85°C
F207
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
to ± 100ppb of final frequency (1 hour reading) @
+25°C
Units
ppb
ppb
ppb
ppb
Units
ppb
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
0 … +70°C
C108
-20 … +70°C
D208
-40 … +70°C
E258
-40 … +85°C
F308
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
to ± 10ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Supply voltage [Option]
Supply voltage [Option]
Power consumption
Min
4.75
11.4
3.135
Typ
5
12.0
3.3
Max.
5.25
12.6
3.465
3.0
1.0
Units
VDC
VDC
VDC
W atts
W atts
Condition
Ordering Code
SV050
SV120
SV033
during warm-up
steady state @ +25°C
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2006-11-10 · page 1 of 5
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax