English
Language : 

UMBF170 Datasheet, PDF (2/2 Pages) Unisonic Technologies – N-CHANNEL ENHANCEMENT MODE
UMBF170
Preliminary
Power MOSFET
„ ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATINGS
UNIT
Drain-Source Voltage
VDSS
60
V
Drain-Gate Voltage (RG=25kΩ)
VDGS
60
V
Gate-Source Voltage
VGSS
±20
V
Continuous Drain Current (VGS=10V)
ID
Peak Drain Current (tP≦10µs)
IDM
300
mA
1.2
A
Power Dissipation
Junction Temperature
Storage Temperature
PD
TJ
TSTG
0.83
W
+150
℃
-65 ~ +150
℃
Note:Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
„ THERMAL DATA
PARAMETER
Junction-to-Ambient
SYMBOL
θJA
RATINGS
350
„ ELECTRICAL CHARACTERISTICS (TJ =25°C, unless otherwise noted)
PARAMETER
SYMBOL
TEST CONDITIONS
OFF CHARACTERISTICS
Drain-Source Breakdown Voltage
BVDSS VGS=0 V, ID=10µA
Drain-Source Leakage Current
IDSS
VDS=48V, VGS=0V
VDS=25V, VGS=0V
Gate-Source Leakage Current
IGSS
VGS= ±15V, VDS=0V
ON CHARACTERISTICS
Gate Threshold Voltage
VGS(TH) VDS=VGS, ID=1mA
Static Drain-Source On-Resistance
RDS(ON)
VGS=10V, ID=300mA
VGS=4.5V, ID=75mA
Forward Transconductance
DYNAMIC PARAMETERS
gFS
VDS=10V, ID=200mA
Input Capacitance
Output Capacitance
CISS
COSS
VDS=10 V, VGS=0 V, f=1MHz
Reverse Transfer Capacitance
SWITCHING PARAMETERS
CRSS
Turn-ON Delay Time
Turn-OFF Delay Time
tD(ON)
tD(OFF)
VDD=50V, VGS=10V, RGS=50Ω
RG=50Ω, RD=250Ω
SOURCE- DRAIN DIODE RATINGS AND CHARACTERISTICS
Diode Forward Voltage
VSD
IS =300mA, VGS=0V
Maximum Body-Diode Continuous Current
Peak Source (Diode Forward) Current
IS
ISM
pulsed; tP≦10µs
Body Diode Reverse Recovery Time
Body Diode Reverse Recovery Charge
tRR
IS=300mA, dI/dt=-100A/μs,
QRR
VGS=0V, VDS=25V
UNIT
K/W
MIN TYP MAX UNIT
60 75
V
0.01 1.0 µA
5 500 nA
10 100 nA
12
V
2.8 5 Ω
3.8 5.3
100 300
mS
25 40 pF
18 30 pF
7.5 10 pF
3 10 ns
12 15 ns
0.85 1.5 V
300 mA
1.2 A
30
ns
30
nC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 2
QW-R502-291.b