UM3352E
Switching Characteristics
(VCC=+5V ± 5%, TA=-40°C to +85°C, unless otherwise noted. Typical values are at VCC=+5V and
TA=+25°C.)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Maximum Data Rate
Driver Input-to-Output
fMAX
tDPLH
tDPHL
Figures 3 and 7, RDIFF=54Ω,
CL1=CL2=100pF
500
kbps
50 1000
ns
50 1000
Driver Output Skew
| tDPLH - tDPHL |
tDSKEW
Figures 3 and 7, RDIFF=54Ω,
CL1=CL2=100pF
15 100 ns
Driver Rise or Fall Time tDR, tDF
Figures 3 and 7, RDIFF=54Ω,
CL1=CL2=100pF
100 750 ns
Driver Enable to Output High tDZH
Figures 4 and 8, CL=100pF,
S2 Closed
30 2500 ns
Driver Enable to Output Low tDZL
Figures 4 and 8, CL=100pF,
S1 Closed
30 2500 ns
Driver Disable Time from
Low
tDLZ
Figures 4 and 8, CL=15pF,
S1 Closed
60 200 ns
Driver Disable Time from
High
tDHZ
Figures 4 and 8, CL=15pF,
S2 Closed
100 200 ns
Receiver Input to Output
Differential
Receiver Skew
| tRPLH - tRPHL |
Receiver Enable to Output
Low
tRPLH,
tRPHL
tRSKD
tRZL
|VID| ≥2.0V,
Rise and Fall Time of VID≤15ns
Figures 6 and 9, |VID| ≥2.0V,
Rise and Fall Time of VID≤15ns
Figures 5 and 10, CL=100pF,
S1 Closed
75 200 ns
0 30 ns
20 50 ns
Receiver Enable to Output
High
tRZH
Figures 5 and 10, CL=100pF,
S2 Closed
20 50 ns
Receiver Disable Time from
Low
tRLZ
Figures 5 and 10, CL=100pF,
S1 Closed
20 50 ns
Receiver Disable Time from
High
tRHZ
Figures 5 and 10, CL=100pF,
S2 Closed
20 50 ns
Time to Shutdown
tSHDN
(Note 4)
200 600 ns
Driver Enable from
Shutdown to Output High
tDZH(SHDN)
Figures 4 and 8, CL=15pF,
S2 Closed
700 4500 ns
Driver Enable from
Shutdown to Output Low
tDZL(SHDN)
Figures 4 and 8, CL=15pF,
S1 Closed
700 4500 ns
Receiver Enable from
Shutdown to Output High tRZH(SHDN)
Figures 5 and 10, CL=100pF,
S2 Closed
700 3500 ns
Receiver Enable from
Shutdown to Output Low tRZL(SHDN)
Figures 5 and 10, CL=100pF,
S1 Closed
700 3500 ns
______
Note 4: The device is put into shutdown by bringing RE high and DE low. If the enable inputs are
in this state for less than 50ns, the device is guaranteed not to enter shutdown. If the enable inputs
are in this state for at least 600ns, the device is guaranteed to have entered shutdown.