UM805 Datasheet, PDF (11/14 Pages) Union Semiconductor, Inc. – Voltage Monitors with Manual Reset Input | |||
|
◁ |
UM805/811/812
______________
UM805 Open-Drain RESET Output Allows Use with Multiple Supplies
Generally, the pull-up connected to the UM805 will connect to the supply voltage that is being
monitored at the ICâs VCC pin. However, some systems may use the open-drain output to level-shift
from the monitored supply to reset circuitry powered by some other supply (Figure 6). Note that as
______________
the UM805âs VCC decreases below 1V, so does the ICâs ability to sink current at RESET. Also,
______________
with any pull-up, RESET will be pulled high as VCC decays toward 0. The voltage where this
occurs depends on the pull-up resistor value and the voltage to which it is connected.
5.0V
3.3V
VCC
UM805
RESET
GND
Rpull-up
VCC
5V System
RESET
GND
______________
Figure 6. UM805 Open-Drain RESET Output Allows Use with Multiple Supplies
________________________________________________________________________
http://www.union-ic.com Rev.01 Jan.2015
11/14
|
▷ |