English
Language : 

PRL1103D Datasheet, PDF (1/4 Pages) ULTRA LEVEL TECH CO., LTD. – AC-DC PFC MEDICAL SWITCHING POWER SUPPLY
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
We Supply the Power Customers Need ISO9001
120W ~ 240W AC-DC PFC MEDICAL SWITCHING POWER SUPPLY
PRL1103D DUAL OUTPUT SERIES
FEATURES:
◆ Compact 240W with 1U height Power Density: 10.41 watts/cu in
◆ Built-in Remote On-Off, Power Good, Fan Fail Alarm
◆ Safety Approvals to IEC/EN/UL60601-1 3rd Edition
◆ Power Factor Corrected to EN61000-3-2 Class D
◆ 5/ 12/ 24V Dual Output Optional Combinations
◆ Variable Fan Speed & Low Acoustical Noise
◆ High Quality & Reliable Component Usage
◆ 3 - Mechanical Options
◆ Full Range AC Input
U Type (U-Chassis only):
3.2(W) x 5(L)x 1.5(H) inches.
E Type (Enclosed with end built-in fan):
3.2(W) x 6.5(L) x 1.6(H) inches
F Type (U-Chassis with top built-in fan ):
3.2(W) x 5(L) x 2(H) inches.
PRODUCT SPECIFICATIONS:
CB
Input Voltage: 90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current: 5A at 90Vac.
Inrush Current: Max. 70A@230Vac & 35A@115Vac; cold start.
Power Factor Correction: PF>0.95 typical.
Transient Response: Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot: Turn-on & off overshoot 5% over nominal voltage.
Efficiency: 75% ~ 87% depends on model.
Turn On Delay: 1 second maximum at 230 Vac.
Hold Up Time: 16mS min. at 80% of full load.
Adjustability: Output user adjustable +/-5% minimum.
Fan Drive: 12VDC/300mA offering to drive an external fan.
Fan Fail (FF) Alarm: Designated as FF on pin 3 of CN3 is a open
collector output rated for 28VDC/5mA sink current maximum, it will
go high when a fan failure is detected.
Remote On-Off: Designated as INH on pin4 of CN3, requires a low
signal to inhibit output.
Power Supply On: Green LED designated as LED1 on the PCB.
Power Good: PG on CN3 goes high 100-500mS after DC regulation
and low at least 1mS before loss of regulation (Open collector).
Input Fusing Protection: Dual T5A/250V fuses inserted in primary.
Over-Power Protection: 110~140% of I-Max; Auto-recovery.
Short Circuit Protection: Trip without damage and auto-recovery.
Over Voltage Protection: Unit latching down when output exceed
130% and recycle AC input to reset.
Over-Temperature Protection: Unit protected of excessive
operating ambient 110 ℃ and automatic recovery.
Switching Frequency: PFC 50K~70K Hz; PWM 45K~55K Hz.
Storage Temperature: -20℃ to 85℃.
Operating Temperature: 0℃ to 70℃ ambient, de-rating at 2.5% per
degree from 50℃ to 70℃.
Operating Humidity: 5% to 90% RH, Non-condensing.
Storage Humidity: 5% to 95% RH, Non-condensing.
EMC: EN60601-1-2 class B conducted / radiated; EN61000-3-2,3;
IEC61000-4-2, 3, 4, 5, 6, 8, 11.
Safety Regulation: EN/ IEC/ UL60601-1 3rd edition.
Vibration: 5 ~ 50 Hz, acceleration 7.35 m/s*s on X,Y and Z Axis.
Leakage Current: < 300uA @ 264Vac.
HI-POT Test: 1500 VAC input line to chassis (10mA DC cut off
current); Isolating 4000VAC primary to secondary windings; Primary
to core 1500VAC. All for 3 sec.
Grounding Test: Apply 25 A from ground pin of the three prong plug
to the far most earth. Max allowable resistance 0.1 ohm.
MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30 ℃ .
Cooling:
U Type: U-Chassis @240W max. with 25CFM airflow or 120W max.
under air convection.
F Type: U-Chassis with top built-in fan @240W max.
E Type: Enclosed with a built-in fan in the input end @240W max.
Burn in: 45 +/- 5 degree C for 1 hour @230Vac with full load.
Enclosure:
U Type: 5(L) x 3.2(W) x 1.5(H) inches.
F Type: 5(L) x 3.2(W) x 2(H)inches.
E Type: 3.2(L) x 6.5(W) x 1.6(H)inches
Weight: Maximum U-type weight is 500g.
Warranty: 2 years.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.