English
Language : 

SUINT3000RTXL3U Datasheet, PDF (2/5 Pages) Tripp Lite. All Rights Reserved – SmartOnline 200-240V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 3U Rack/Tower, USB, DB9 Serial
Maintains AC output at near-perfect levels even during long-duration brownouts as low as 160V and overvoltages to 275V without using battery power.
Brownout support extends to 130V when loaded to 70% or less
Set of internal batteries supports connected equipment during power failures for 14 minutes at half load (1500VA/1200W) and 5 minutes at full load
(3000VA/2400W)
Expandable battery runtime with the addition of external battery packs BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible) and BP72V18-2US
(multi-pack compatible)
Intelligent DB9 monitoring port communicates site power and UPS status information including line power status, input voltage, battery status, load level
and more - with full support for applications requiring basic contact closure power-fail and low-battery messaging
FREE bundled PowerAlert software compatible with stand-alone and network operating systems offers unattended shutdown, remote monitoring and
control of UPS system and connected equipment
Slot for SNMPWEBCARD enables remote monitoring and UPS control via network management stations or web browser interface (#SNMPWEBCARD)
Emergency Power Off (EPO) support available; contact Tripp Lite
Includes 10 outlets (8 IEC320-C13 and 2 IEC320-C19)
1 C19 to C20 and 2 C13 to C14 power cables included
Two separate banks of individually controllable outlets enable remote reboot of locked network equipment without disrupting power to other loads;
accessible via PowerAlert, NMS or enabled web browser - also supports automatic load shedding of non-essential items to extend battery runtime for
critical equipment
Compatible with Tripp Lite's WatchDog system service software
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Front panel LEDs and audible alarm provide notification of power status and full UPS status information
Optional 2POSTRMKITHD enables 2 post rackmount installation
Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
CE Certified
Specifications
OUTPUT
Output Capacity Details
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30
seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power
3000
3
2400
2.4
0.8
3:1
200V; 220V; 230V; 240V
230V default
50 / 60 Hz
Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start
2/5