SUINT2200RTXL2UA Datasheet, PDF (2/6 Pages) Tripp Lite. All Rights Reserved – SmartOnline 200-240V 2.2kVA 1.6kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 2U Rack/Tower, USB, DB9 Serial
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 130V and as high as 275V back to selectable 200/208/220/230/240V (+/-3%) values
Highly efficient operation in optional Economy Mode setting, saving BTU heat output and energy costs.
Standard internal battery set offers 14 minutes runtime at half load (800W) and 5 minutes at full load (1600W)
Extended Runtime with BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 483 mm
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number
of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment
and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
C20 inlet power connection / C19 and C13 output receptacles
C20 inlet accepts user-suppplied AC power cord with country-specific plug
Includes 2 C13 to C14 and 1 C19 to C20 output power cables
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (both of the C19 outlets
are individually controllable)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection ofinternal batteries by user required
Single line TEL/DSL or network ethernet line surge suppression
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
2200
2.2
1600
1.6
0.7
3:1
200V; 220V; 230V; 240V
230V default
50 / 60 Hz
2/6