English
Language : 

TCD6001 Datasheet, PDF (7/43 Pages) Tripath Technology Inc. – 6 CHANNEL CLASS-T DIGITAL AUDIO PROCESSOR USING DIGITAL POWER PROCESSINGTM TECHNOLOGY
TCD6001 Pin Description
Tripath Technology, Inc. – Preliminary Technical Information
Pin
Function
Type
Description
1
VNNSENSE
Input
Overvoltage and Undervoltage sensing for the VNN supply.
2
GA
Ground
Analog Ground
3
FB1N
Input
Switching feedback
4
FB1P
Input
Switching feedback
5
NC
Float
Not internally connected
6
NC
Float
Not internally connected
7
FB2P
Input
Switching feedback
8
FB2N
Input
Switching feedback
9
FAULT
Input
3-level digital input to detect power stage fault condition
10
FB3N
Input
Switching feedback
11
FB3P
Input
Switching feedback
12
FB4P
Input
Switching feedback
13
FB4N
Input
Switching feedback
14
AM_OUT
5V Logic Output
Used to activate AM mode on external power stage
15
HMUTE
5V Logic Output
Indicates processor channels are muted. Polarity is selectable.
16
Y4B
5V Logic Output
Switching modulator output
17
Y4
5V Logic Output
Switching modulator output
18
Y3B
5V Logic Output
Switching modulator output
19
Y3
5V Logic Output
Switching modulator output
20
Y2B
5V Logic Output
Switching modulator output
21
Y2
5V Logic Output
Switching modulator output
22
NC
Float
Not internally connected
23
NC
Float
Not internally connected
24
Y1B
5V Logic Output
Switching modulator output
25
Y1
5V Logic Output
Switching modulator output
26
NC
Float
Not internally connected
27
NC
Float
Not internally connected
28 SLEEPB_OUT 5V Logic Output
Digital Output used to activate sleep mode on external power stage
29
GA
Ground
Analog Ground
30 HMUTE_SET 5V Logic Input
Determines the state of HMUTE (pin 15) during a fault condition. If
HMUTE_SET is cleared to 0, the HMUTE will be low during a fault
condition. If HMUTE_SET is set to 1, then HMUTE will be high during a
fault condition.
31
OVRLDB
5V Logic Output
Indicates that one or more channels are near saturation
32
TST_EN
5V Logic Output
Digital output to put power stage in to test mode. Can be used as a
general purpose I/O during normal operation.
33
BYP_CAL
5V Logic Input If BYP_CAL is set to 1, the automatic DC calibration function is disabled.
If BYP_CAL is set to 0, the DC calibration function is performed at startup.
34
VA50
Power
5V analog power supply
35
GA50
Ground
Analog ground for VA50
36
AM_IN
5V Logic Input
If AM_IN is set to 1, the system uses AM mode.
37
SE/BRGB
5V Logic Input
Sets DCB control bit power up defaults and selects VCLAMP_SE or
VCLAMP_BR
38, GAIN0, GAIN1 5V Logic Input
Digital inputs which set the power up default modulator gain. GAIN0,
39
GAIN1=0 set the lowest gain, while GAIN0,GAIN1=1 set the highest gain
which is used for maximum output power for bridged applications.
40
TEST
Float
Test pin – must be kept floating
41
NC
Float
Not internally connected
42
GA
Ground
Analog ground
43
VA33
Power
3.3V analog power supply
44
VA33
Power
3.3V analog power supply
45
NC
Float
Not internally connected
46
GA
Ground
Analog ground
47
GA
Ground
Analog ground
48
GD
Ground
Digital ground
49
VD18CAP
Output
Decoupling point for internal 1.8V regulator
50
VD33
Power
3.3V digital power supply
51
TEST
Float
Test pin – must be kept floating
52
NC
Float
Not internally connected
53
NC
Float
Not internally connected
54
NC
Float
Not internally connected
55
NC
Float
Not internally connected
56
GA
Ground
Analog ground
57
GA
Ground
Analog ground
7
TCD6001 – JL/Rev. 0.9/07.05