English
Language : 

TMC603A Datasheet, PDF (33/44 Pages) TRINAMIC Motion Control GmbH & Co. KG. – Three phase motor driver with BLDC back EMF commutation hallFX™ and current sensing
TMC603A DATA SHEET (V. 1.15 / 2009-Nov-19)
33
NMOS high side driver
note 1)
Parameter
DC-Characteristics
VVCC = 5.0 V, VVLS = 12V, VCPD = 10.5V
Symbol Conditions
Min
Gate drive current HSx
high side switch ON
IHSON
VHSX = 5V
RSLP = 68k
Gate drive current HSx
high side switch OFF
IHSOFF
VHSX = VM+5V
RSLP = 68k
Gate drive current HSx
high side switch ON
IHSON
VHSX = 5V
75
RSLP = 100k
Gate drive current HSx
high side switch OFF
IHSOFF VHSX = VM+5V
-75
RSLP = 100k
Gate drive current HSx
high side switch ON
IHSON
VHSX = 5V
RSLP = 220k
Gate drive current HSx
high side switch OFF
IHSOFF
VHSX = VM+5V
RSLP = 220k
Gate Off detector threshold high
side VHSX-VBMX, BM level high
VGOD
VHSX falling
VBMX > VGOBM
Gate Off detector threshold high
side VBMX, BM level low
VGOBM VBMX falling
QGD protection current after
detection of gate off
IHSOFFQGD VBMX = 24V
VHSX = VBMX+2V
Delay HS driver switch on
tHSON
RSLP = 100k
75
BHx to HSx at 50%
VM = 24V
CHSX = 100pF
Delay HS driver switch off
tHSOFF RSLP = 100k
60
BHx to HSx at 50%
VM = 24V
CHSX = 100pF
Break-before-make block
note 1)
Timing-Characteristics
VVM = 48 V, RSLP = 100K
Parameter
Symbol Conditions
Min
Break-before-make delay LSx off
to HSx on
tBBMLH
Measured at 1V
gate-source voltage
Break-before-make delay HSx
off to LSx on
tBBMHL
Measured at 1V
gate-source voltage
1) See timing diagram in figure 6: bridge driver timing
Typ
150
-150
100
-100
50
-50
0
3.5
300
150
120
Typ
160
290
Max Unit
mA
mA
150 mA
-125 mA
mA
mA
V
V
mA
300
ns
240
ns
Max Unit
ns
ns
Copyright © 2009 TRINAMIC Motion Control GmbH & Co. KG