SPECIFICATION
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH3,4 are isolated from other outputs and the polarity can be reversed
No minimum load requirement for CH2,3,4
All output can be adjustable from -5~+10%
With power good and fail signal output
Built-in remote ON-OFF control
Fixed switching frequency at 100KHz
3 years warranty
..
MODEL
QP-375-5A
QP-375-5B
QP-375-5C
OUTPUT NUMBER
DC VOLTAGE
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
5V
+12V 12V
12V
+5V
+12V 12V
5V
5V
+12V 15V
15V
RATED CURRENT
30A
10A
6A
3A
30A
10A
6A
3A
30A
9A
4A
4A
CURRENT RANGE
3.5 ~ 40A 0 ~ 16A 0 ~ 6A 0 ~ 3A 3.5 ~ 40A 0 ~ 16A 0 ~ 6A 0 ~ 3A 3.5 ~ 40A 0 ~ 16A 0 ~ 4A 0 ~ 4A
RATED POWER(max.)
378W
357W
378W
RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 50mVp-p 100mVp-p 120mVp-p 120mVp-p 50mVp-p 100mVp-p 150mVp-p 150mVp-p 240mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V 11.4 ~ 13.2V 4.75 ~ 5.5V 11.4 ~ 13.2V 11.4 ~ 13.2V ------ 4.75 ~ 5.5V 11.4 ~ 13.2V 14.3 ~ 16.5V 14.3 ~ 16.5V
VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8% 0.8%
800ms, 50ms at full load
HOLD UP TIME (Typ.)
36ms at full load
VOLTAGE RANGE Note.7 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
77%
77%
77%
AC CURRENT (Typ.)
6A/115VAC 3A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
80 5 (TSW1) Detect on heatsink of Q1,Q2 power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
FUNCTION
REMOTE CONTROL
RC+/RC-:0 ~ 0.8V POWER ON; 4V ~ 10V POWER OFF
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 Approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
75.9K hrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
280*127*63.5mm (L*W*H)
PACKING
2.4Kg; 6pcs/14.8Kg/1.45CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Peak current can not exceed 60 sec.
6. Isolated CH3 & CH4 maybe series connected or can be used as positive or negative outputs.
7. Derating may be needed under low input voltages. Please check the derating curve for more details.