English
Language : 

XC6120_2 Datasheet, PDF (4/13 Pages) Torex Semiconductor – Highly Accurate, Ultra Small, Low Power Consumption Voltage Detector
XC6120 Series
■ELECTRICAL CHARACTERISTICS (Continued)
● DETECT VOLTAGE ACCURACY AND SUPPLY CURRENT SPECIFICATIONS
SYMBOL
PARAMETER
SETTING DETECT
VOLTAGE
VDF(T)
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
4.0
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
5.0
E-1
DETECT VOLTAGE
VDF (V)
XC6120xxx2 Series
MIN.
0.970
1.070
1.170
1.270
1.370
1.470
1.568
1.666
1.764
1.862
1.960
2.058
2.156
2.254
2.352
2.450
2.548
2.646
2.744
2.842
2.940
3.038
3.136
3.234
3.332
3.430
3.528
3.626
3.724
3.822
3.920
4.018
4.116
4.214
4.312
4.410
4.508
4.606
4.704
4.802
4.900
MAX.
1.030
1.130
1.230
1.330
1.430
1.530
1.632
1.734
1.836
1.938
2.040
2.142
2.244
2.346
2.448
2.550
2.652
2.754
2.856
2.958
3.060
3.162
3.264
3.366
3.468
3.570
3.672
3.774
3.876
3.978
4.080
4.182
4.284
4.386
4.488
4.590
4.692
4.794
4.896
4.998
5.100
E-2
SUPPLY CURRENT 1
ISS1 (μA)
TYP.
MAX.
E-3
SUPPLY CURRENT 2
ISS2 (μA)
TYP.
MAX.
0.5
1.4
0.4
1.35
0.6
1.7
0.5
1.60
0.7
1.9
0.6
1.80
(※6 )When setting detect voltage is 1.0V≦VDF(T)<1.5V, detect accuracy is ±30mV.
When setting detect voltage is 1.5V≦VDF(T)≦5.0V, detect accuracy is ±2%.
4/13