English
Language : 

VCA810_16 Datasheet, PDF (9/40 Pages) Texas Instruments – VCA810 High Gain Adjust Range, Wideband and Variable Gain Amplifier
www.ti.com
VCA810
SBOS275G – JUNE 2003 – REVISED DECEMBER 2015
7.6 High Grade DC Characteristics: VS = ±5 V (VCA810AID)
At RL = 500 Ω and VIN = single-ended input on V+ with V− at ground, unless otherwise noted.
PARAMETER
TEST CONDITIONS
TEST LEVEL(1)
MIN
DC PERFORMANCE (Single-Ended or Differential Input)
TJ = 25°C
Output offset voltage
−2 V < VC < 0 V
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
TJ = 25°C
TJ = 25°C(2)
Input offset voltage
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
TJ = 25°C
TJ = 25°C(2)
Input offset current
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
GAIN CONTROL (VC, Pin 3, Single-Ended or Differential Input)
TJ = 25°C
−1.8 V ≤ VC ≤ −0.2 V
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
Gain accuracy
TJ = –40°C to 85°C(3)
TJ = 25°C
TJ = 25°C(2)
VC < −1.8 V, VC > −0.2 V
TJ = 0°C to 70°C(3)
A
TJ = –40°C to 85°C(3)
TJ = 25°C
−1.8 V ≤ VC ≤ 0 V
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
Gain control linearity(4)
TJ = –40°C to 85°C(3)
TJ = 25°C
VC < −1.8 V
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
POWER SUPPLY
Positive maximum supply
quiescent current
+VS = 5 V, G = −40 dB
+VS = 5 V, G = 40 dB
Positive minimum supply
quiescent current
+VS = 5 V, G = −40 dB
+VS = 5 V, G = 40 dB
TJ = 25°C
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
TJ = 25°C
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
TJ = 25°C
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
TJ = 25°C
TJ = 25°C(2)
A
TJ = 0°C to 70°C(3)
TJ = –40°C to 85°C(3)
11.5
11.6
11.7
19.5
21
21.3
TYP
±4
±0.1
±100
±0.4
±0.5
±0.3
±0.7
10
MAX UNIT
±14
mV
±24
±26
±0.2
mV
±0.25
±0.3
±500
nA
±600
±700
±0.9
dB
±1.9
±2.9
±1.5
dB
±3.0
±4.0
±0.6
dB
±0.7
±0.8
±1.1
dB/V
±1.9
±2.7
mA
18
mA
10
8.5
mA
8.2
8.1
18
16.5
mA
15.5
14.5
(1) Test levels: (A) 100% tested at 25°C. Over temperature limits set by characterization and simulation. (B) Limits set by characterization
and simulation. (C) Typical value; only for information.
(2) Junction temperature = ambient for 25°C tested specifications.
(3) Junction temperature = ambient at low temperature limit; junction temperature = ambient 30°C at high temperature limit for over
temperature specifications.
(4) Maximum deviation from best line fit.
Copyright © 2003–2015, Texas Instruments Incorporated
Submit Documentation Feedback
9
Product Folder Links: VCA810