English
Language : 

TLC2551_16 Datasheet, PDF (8/28 Pages) Texas Instruments – 5-V, LOW-POWER, 12-BIT, 175/360 KSPS, SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTOPOWER DOWN
TLC2551, TLC2552, TLC2555
5-V, LOW-POWER, 12-BIT, 175/360 KSPS,
SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTOPOWER DOWN
SLAS276D – MARCH 2000 – REVISED MAY 2003
ICC
With 1-µF/0.1-µF Capacitor Between Supply and Ground
VDD = 5 V
0.5 µS
3.5 mA
2 mS
8 µA
1 µA
t(Powerdown) – Powerdown time – S
Table 1. Modes of Operation and Data Throughput
CONTROL PIN(s)/DEVICE
CS control only (TLC2551 only)
For SPI†
DSP interface‡
CS and FS control (TLC2551 only)§
DSP interface
† See Figure 21(a).
‡ See Figure 21(b).
§ See Figure 21(c).
MAX SCLK (MHz)
(50/50 duty cycle)
VDD = 4.5 V
15
8
20
APPROXIMATE CONVERSION
THROUGHPUT (ksps)
VDD = 4.5 V
333
175
400
absolute maximum ratings over operating free-air temperature (unless otherwise noted)¶
Supply voltage range, GND to VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6.5 V
Analog input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VDD + 0.3 V
Reference input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDD + 0.3 V
Digital input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VDD+ 0.3 V
Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 150°C
Operating free-air temperature range, TA: C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
¶ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
8
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265