Operating Modes
The MSP430 has one active mode and five software selectable low-power modes of operation. An interrupt
event can wake up the device from any of the low-power modes, service the request, and restore back to the
low-power mode on return from the interrupt program.
The following six operating modes can be configured by software:
⢠Active mode (AM)
â All clocks are active.
⢠Low-power mode 0 (LPM0)
â CPU is disabled.
â ACLK and SMCLK remain active.
â MCLK is disabled.
⢠Low-power mode 1 (LPM1)
â CPU is disabled
â ACLK and SMCLK remain active.
â MCLK is disabled.
â DCO's dc generator is disabled if DCO not used in active mode.
⢠Low-power mode 2 (LPM2)
â CPU is disabled.
â ACLK remains active.
â MCLK and SMCLK are disabled.
â DCO's dc generator remains enabled.
⢠Low-power mode 3 (LPM3)
â CPU is disabled.
â ACLK remains active.
â MCLK and SMCLK are disabled.
â DCO's dc generator is disabled.
⢠Low-power mode 4 (LPM4)
â CPU is disabled.
â ACLK, MCLK, and SMCLK are disabled.
â DCO's dc generator is disabled.
â Crystal oscillator is stopped.
8
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links: MSP430G2955 MSP430G2855 MSP430G2755
|
▷ |