LM358NS Datasheet, PDF (8/32 Pages) Texas Instruments – DUAL OPERATIONAL AMPLIFIERS
LM158, LM158A, LM258, LM258A
LM358, LM358A, LM2904, LM2904V
DUAL OPERATIONAL AMPLIFIERS
SLOS068R − JUNE 1976 − REVISED JULY 2010
electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
LM158A
LM258A
TA‡
MIN TYP§ MAX MIN TYP§ MAX UNIT
VIO
aVIO
IIO
Input offset voltage
Average
temperature
coefficient of
input offset voltage
Input offset current
VCC = 5 V to 30 V,
VIC = VICR(min),
VO = 1.4 V
VO = 1.4 V
25°C
Full range
Full range
25°C
Full range
2
4
7 15*
2
10
30
2
3
mV
4
7
15 µV/°C
2
15
nA
30
aIIO
IIB
VICR
VOH
VOL
Average
temperature
coefficient of
input offset current
Input bias current
Common-mode
input voltage range
High-level
output voltage
Low-level
output voltage
Full range
10 200
10 200 pA/°C
VO = 1.4 V
25°C
Full range
−15 −50
−100
−15 −80
nA
−100
25°C
0 to
VCC − 1.5
0 to
VCC − 1.5
VCC = 30 V
Full range
0 to
VCC − 2
0 to
VCC − 2
V
RL ≥ 2 kΩ
25°C
VCC − 1.5
VCC − 1.5
VCC = 30 V
RL = 2 kΩ Full range
RL ≥ 10 kΩ Full range
26
27
28
26
V
27
28
RL ≤ 10 kΩ
Full range
5
20
5
20 mV
AVD
CMRR
Large-signal
differential
voltage amplification
Common-mode
rejection ratio
VCC = 15 V,
VO = 1 V to 11 V,
RL ≥ 2 kΩ
25°C
Full range
25°C
50 100
25
70
80
50 100
25
70
80
V/mV
dB
kSVR
VO1/VO2
Supply-voltage
rejection ratio
(∆VDD/∆VIO)
Crosstalk
attenuation
f = 1 kHz to 20 kHz
25°C
25°C
65 100
120
65 100
dB
120
dB
VCC = 15 V,
25°C
−20 −30 −60 −20 −30 −60
VID = 1 V,
Source
VO = 0
Full range −10
−10
mA
IO
Output current
VCC = 15 V,
25°C
10
20
10
20
VID = −1 V, Sink
VO = 15
Full range
5
5
VID = −1 V, VO = 200 mV
25°C
12
30
12
30
µA
IOS
Short-circuit output
current
VCC at 5 V, GND at −5 V,
VO = 0
25°C
±40 ±60
±40 ±60 mA
ICC
Supply current (two
amplifiers)
VO = 2.5 V, No load
VCC = MAX, VO = 0.5 V,
No load
Full range
Full range
0.7 1.2
1
2
0.7 1.2
mA
1
2
*On products compliant to MIL-PRF-38535, this parameter is not production tested.
† All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX VCC for
testing purposes is 26 V for LM2904 and 30 V for others.
‡ Full range is −55°C to 125°C for LM158A, −25°C to 85°C for LM258A, and 0°C to 70°C for LM358A.
§ All typical values are at TA = 25°C.
8
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265