English
Language : 

LM358NS Datasheet, PDF (7/32 Pages) Texas Instruments – DUAL OPERATIONAL AMPLIFIERS
LM158, LM158A, LM258, LM258A
LM358, LM358A, LM2904, LM2904V
DUAL OPERATIONAL AMPLIFIERS
SLOS068R − JUNE 1976 − REVISED JULY 2010
electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
LM2904
TA‡
MIN TYP§ MAX UNIT
VIO
Input offset voltage
VCC = 5 V to MAX,
VIC = VICR(min),
VO = 1.4 V
Non-A devices
A-suffix devices
25°C
Full range
25°C
Full range
3
7
10
mV
1
2
4
aVIO
Average temperature coefficient
of input offset voltage
Full range
7
µV/°C
IIO
Input offset current
VO = 1.4 V
Non-V device
V-suffix device
25°C
Full range
25°C
Full range
2
50
300
nA
2
50
150
aIIO
Average temperature coefficient
of input offset current
Full range
10
pA/°C
IIB
Input bias current
VO = 1.4 V
25°C
Full range
−20 −250
nA
−500
VICR
Common-mode input voltage
range
VOH
High-level output voltage
VOL
Low-level output voltage
Large-signal differential
AVD
voltage amplification
VCC = 5 V to MAX
RL ≥ 10 kΩ
VCC = MAX,
Non-V device
VCC = MAX,
V-suffix device
RL ≤ 10 kΩ
RL = 2 kΩ
RL ≥ 10 kΩ
RL = 2 kΩ
RL ≥ 10 kΩ
VCC = 15 V, VO = 1 V to 11 V,
RL ≥ 2 kΩ
25°C
Full range
25°C
Full range
Full range
Full range
Full range
Full range
25°C
Full range
0 to
VCC − 1.5
0 to
VCC − 2
VCC − 1.5
22
23
24
26
27
28
5
25
100
15
V
V
20 mV
V/mV
CMRR Common-mode rejection ratio
VCC = 5 V to MAX,
VIC = VICR(min)
Non-V device
V-suffix device
25°C
25°C
50
80
65
80
dB
kSVR
Supply-voltage rejection ratio
(∆VDD/∆VIO)
VCC = 5 V to MAX
25°C
65
100
dB
VO1/VO2 Crosstalk attenuation
f = 1 kHz to 20 kHz
25°C
120
dB
VCC = 15 V,
VID = 1 V, VO = 0
Source
25°C
−20
−30
Full range −10
mA
mA
IO
Output current
VCC = 15 V,
VID = −1 V,
VO = 15 V
Sink
25°C
10
20
mA
Full range
5
mA
VID = −1 V,
VO = 200 mV
Non-V device
V-suffix device
25°C
25°C
30
12
40
µA
IOS
Short-circuit output current
VCC at 5 V, GND at −5 V, VO = 0
25°C
±40 ±60 mA
ICC
Supply current (two amplifiers)
VO = 2.5 V, No load
VCC = MAX, VO = 0.5 V, No load
Full range
Full range
0.7 1.2
mA
1
2
† All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX VCC for
testing purposes is 26 V for the LM2904, 32 V for the LM2904V, and 30 V for others.
‡ Full range is −55°C to 125°C for LM158, −25°C to 85°C for LM258, 0°C to 70°C for LM358, and −40°C to 125°C for LM2904.
§ All typical values are at TA = 25°C.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7