English
Language : 

BQ2085-V1P2 Datasheet, PDF (8/56 Pages) Texas Instruments – SBS-COMPLIANT GAS GAUGE IC FOR USE WITH THE bq29311
bq2085−V1P2
SLUS590 − DECEMBER 2003
www.ti.com
Charge and Discharge Counting
The integrating ADC measures the charge and discharge flow of the battery by monitoring a small-value sense
resistor between the SR1 and SR2 pins as shown in the schematic. The integrating ADC measures bipolar
signals from −0.3 to 1.0 V. The bq2085−V1P2 detects charge activity when VSR = V(SR1)–V(SR2) is positive and
discharge activity when VSR = V(SR1)–V(SR2) is negative. The bq2085−V1P2 continuously integrates the signal
over time, using an internal counter. The fundamental rate of the counter is 2.6 nVh. The bq2085−V1P2 updates
Remaining Capacity() with the charge or discharge accumulated in this internal counter once every second.
Offset Calibration
The bq2085−V1P2 provides an autocalibration feature to cancel the voltage offset error across SR1 and SR2
for maximum charge measurement accuracy. The bq2085−V1P2 performs autocalibration when the SMBus
lines stay low for a minimum of 20 s. The bq2085−V1P2 is capable of automatic offset calibration down to 1 µV.
Digital Filter
The bq2085−V1P2 does not measure charge or discharge counts below the digital filter threshold. The digital
filter threshold is programmed in the Digital Filter DF 0x2b. Set it sufficiently high to prevent false signal detection
with no charge or discharge flowing through the sense resistor.
Voltage
While monitoring SR1 and SR2 for charge and discharge currents, the bq2085−V1P2 monitors the individual
series cell voltages through the bq29311. The bq2085−V1P2 configures the bq29311 to present the selected
cell to the VCELL pin of the bq29311. Therefore, connect the VCELL pin to VIN of the bq2085−V1P2. The
internal ADC of the bq2085−V1P2 then measures the voltage and scales it appropriately. The bq2085−V1P2
then reports the Voltage( ) and the individual cell voltages in VCELL1, VCELL2, VCELL3, and VCELL4 located
in 0x3c−0x3f.
Current
The bq2085−V1P2 uses the SR1 and SR2 inputs to measure and calculate the battery charge and discharge
current as represented in the data register Current().
Temperature
The TS input of the bq2085−V1P2 in conjunction with an NTC thermistor measures the battery temperature
as shown in the schematic. The bq2085−V1P2 reports temperature in Temperature( ).
The bq2085−V1P2 can also be configured to use its internal temperature sensor by setting the IT bit in Misc
Configuration DF 0x2a. Data flash locations DF 0xa4 through DF 0xad also have to be changed to prescribed
values if the internal temperature sensor option is selected.
Table 1. Data Flash Settings for Internal or External Temperature Sensor
LABEL
LOCATION
Dec (Hex)
INTERNAL TEMP SENSOR SETTING
Dec (Hex)
EXTERNAL TEMP SENSOR SETTING
(Semitec 103AT)
Dec (Hex)
Misc. Configuration
42 (0x2a)
Bit 7 = 1
Bit 7 = 0
TS Const1 A3
164/5 (0xa4/5)
0 (0x0000)
−28285 (0x9183)
TS Const2 A2
166/7 (0xa6/7)
0 (0x0000)
20848 (0x5170)
TS Const3 A1
168/9 (0xa8/9)
−11136 (0xd480)
−7537 (0xe28f)
TS Const4 A0
170/1 (0xaa/b)
5754 (0x1666)
4012 (0x0fac)
Min Temp AD
172/3 (0xac/d)
0 (0x0000)
0 (0x0000)
Max Temp
174/5 (0xae/f)
5734 (0x1666)
4012 (0x0fac)
If AD < Min Temp AD then Temp = Max Temp
Else
Temp = ([A3 × AD × 2^ − 16 + A2] × AD × 2^ − 16 + A1) × AD 2^ −16 + A0
8