English
Language : 

TLC252_16 Datasheet, PDF (7/26 Pages) Texas Instruments – LinCMOS DUAL OPERATIONAL AMPLIFIERS
TLC252, TLC252A, TLC252B, TLC252Y, TLC25L2, TLC25L2A, TLC25L2B
TLC25L2Y, TLC25M2, TLC25M2A, TLC25M2B, TLC25M2Y
LinCMOS DUAL OPERATIONAL AMPLIFIERS
SLOS002I – JUNE 1983 – REVISED MARCH 2001
electrical characteristics at specified free-air temperature, VDD = 10 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC252C, TLC252AC,
TA†
TLC252BC
UNIT
MIN TYP MAX
TLC252C
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 10 kΩ
25°C
Full range
1.1
10
12
VIO
Input offset voltage
TLC252AC
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 10 kΩ
25°C
Full range
0.9
5
mV
6.5
TLC252BC
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 10 kΩ
25°C
Full range
0.29
2
3
αVIO
Average temperature coefficient of input
offset voltage
25°C to 70°C
2
µV/°C
IIO
Input offset current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
70°C
0.1
60
pA
7 300
IIB
Input bias current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
70°C
0.6
60
pA
50 600
VICR
Common-mode input voltage
range (see Note 5)
– 0.2 – 0.3
25°C
to
to
V
9 9.2
– 0.2
Full range
to
V
8.5
25°C
8 8.5
VOH High-level output voltage
VID = 100 mV,
RL = 10 kΩ
0°C
8 8.5
V
70°C
7.8 8.4
25°C
0
50
VOL Low-level output voltage
VID = – 100 mV, IOL = 0
0°C
70°C
0
50 mV
0
50
AVD
Large-signal differential voltage
amplification
VO = 1 V to 6 V, RL = 10 kΩ
25°C
0°C
70°C
10
36
7.5
42
7.5
32
V/mV
25°C
65
85
CMRR Common-mode rejection ratio
VIC = VICRmin
0°C
60
88
dB
70°C
60
88
kSVR
Supply-voltage rejection ratio
(∆VDD /∆VDD)
25°C
65
95
VDD = 5 V to 10 V, VO = 1.4 V
0°C
60
94
dB
70°C
60
96
25°C
1.9
IDD
Supply current (two amplifiers)
VO = 5 V,
No load
VIC = 5 V,
0°C
2.3
70°C
1.6
† Full range is 0°C to 70°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.
4
4.4 mA
3.4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265