TLC2264A-Q1 Datasheet, PDF (7/37 Pages) Texas Instruments – Advanced LinCMOS™ RAIL-TO-RAIL OPERATIONAL ANPLIFIERS | |||
|
◁ |
Ä
TLC226xÄQ1, TLC226xAÄQ1
Advanced LinCMOS RAILÄTOÄRAIL
OPERATIONAL AMPLIFIERS
SGLS189B â OCTOBER 2003 â REVISED APRIL 2008
TLC2262 electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TAâ
TLC2262-Q1
MIN TYP MAX
TLC2262A-Q1
UNIT
MIN TYP MAX
VIO Input offset voltage
25°C
Full range
300 2500
3000
300 950
µV
1500
αVIO
Temperature coefficient of
input offset voltage
Full range
5
5
µV/°C
Input offset voltage long-
term drift (see Note 4)
VIC = 0,
RS = 50 â¦
VO = 0,
IIO
Input offset current
IIB
Input bias current
25°C
25°C
125°C
25°C
125°C
0.003
0.5
800
1
800
0.003
0.5
1
µV/mo
pA
800
pA
800
VICR
Common-mode input
voltage range
RS = 50 â¦,
|VIO| ⤠5 mV
25°C
Full range
â5
to 4
â5
to 3.5
â 5.3
to 4
â5
to 4
â5
to 3.5
â 5.3
to 4.2
V
Maximum positive peak
VOM + output voltage
IO = â 20 µA
IO = â 100 µA
IO = â 400 µA
25°C
4.99
4.99
25°C
4.85 4.94
4.85 4.94
Full range 4.82
4.82
V
25°C
4.7 4.85
4.7 4.85
Full range 4.5
4.5
VIC = 0,
IO = 50 µA
25°C
â 4.99
â 4.99
25°C â4.85 â4.91
â4.85 â4.91
Maximum negative peak
VOM â output voltage
VIC = 0,
IO = 500 µA Full range â4.85
â 4.85
V
25°C
â4 â4.3
â4 â4.3
VIC = 0,
IO = 4 mA
Full range â3.8
â 3.8
Large-signal differential
AVD voltage amplification
ri(d)
Differential input
resistance
VO = ± 4 V
RL = 50 kâ¦
RL = 1 Mâ¦
25°C
Full range
25°C
25°C
80 200
50
1000
1012
80 200
50
1000
1012
V/mV
â¦
Common-mode input
ri(c) resistance
25°C
1012
1012
â¦
ci(c)
Common-mode input
capacitance
f = 10 kHz, P package
25°C
8
8
pF
zo
Closed-loop output
impedance
f = 100 kHz, AV = 10
25°C
220
220
â¦
CMRR
Common-mode
rejection ratio
VIC = â 5 V to 2.7 V,
25°C
75
88
VO = 0,
RS = 50 ⦠Full range
75
75
88
dB
75
kSVR
Supply-voltage rejection
ratio (âVDD ± /âVIO)
VDD = 4.4 V to 16 V,
VIC = VDD /2, No load
25°C
80
95
Full range
80
80
95
dB
80
IDD Supply current
VO = 0,
No load
25°C
Full range
425 500
500
425 500
500 µA
â Full range is â40°C to 125°C for Q suffix.
NOTE 4: Typical values are based on the input offset voltage shift observed through 500 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7
|
▷ |