TLC2252-EP Datasheet, PDF (7/38 Pages) Texas Instruments – Advanced LinCMOS™ RAIL-TO-RAIL VERY LOW-POWER OPERATIONAL AMPLIFIERS | |||
|
◁ |
Ä
TLC225xÄEP, TLC225xAÄEP
Advanced LinCMOS RAILÄTOÄRAIL
VERY LOWÄPOWER OPERATIONAL AMPLIFIERS
SGLS216 â NOVEMBER 2003
electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC2252-EP
TLC2252A-EP
TAâ
UNIT
MIN TYP MAX MIN TYP MAX
VIO Input offset voltage
25°C
Full range
200 1500
1750
200 850
µV
1000
αVIO
Temperature coefficient of
input offset voltage
25°C
to 125°C
0.5
0.5
µV/°C
Input offset voltage long-
term drift (see Note 4)
VIC = 0,
VO = 0,
RS = 50 â¦
IIO
Input offset current
25°C
25°C
Full range
0.003
0.5
60
1000
0.003
µV/mo
0.5
60
pA
1000
IIB
Input bias current
25°C
Full range
1
60
1000
1
60
pA
1000
â5 â5.3
â5 â5.3
25°C
to
to
to
to
Common-mode input
VICR voltage range
RS = 50 â¦, |VIO | ⤠5 mV
4 4.2
â5
4 4.2
V
â5
Full range
to
to
3.5
3.5
Maximum positive peak
VOM + output voltage
IO = â 20 µA
IO = â 100 µA
25°C
4.98
4.98
25°C
4.9 4.93
4.9 4.93
V
Full range 4.7
4.7
IO = â 200 µA
25°C
4.8 4.86
4.8 4.86
VIC = 0,
IO = 50 µA
25°C
â 4.99
â 4.99
25°C â4.85 â4.91
â4.85 â4.91
Maximum negative
VOM â peak output voltage
VIC = 0,
IO = 500 µA Full range â4.85
â 4.85
V
25°C
â4 â4.3
â4 â4.3
VIC = 0,
IO = 4 mA
Full range â3.8
â 3.8
Large-signal differential
AVD voltage amplification
rid
Differential input
resistance
VO = ± 4 V
RL = 100 kâ¦
RL = 1 Mâ¦
25°C
Full range
25°C
25°C
40 150
10
3000
1012
40 150
10
3000
1012
V/mV
â¦
ric
Common-mode input
resistance
25°C
1012
1012
â¦
cic
Common-mode input
capacitance
f = 10 kHz, P package
25°C
8
8
pF
zo
Closed-loop output
impedance
f = 25 kHz, AV = 10
25°C
190
190
â¦
Common-mode
CMRR rejection ratio
VIC = â 5 V to 2.7 V,
25°C
75
88
VO = 0,
RS = 50 â¦
Full range
75
75
88
dB
75
Supply-voltage rejection
kSVR ratio (âVDD ± /âVIO)
VDD = ±2.2 V to ±8 V,
VIC = 0,
No load
25°C
80
95
Full range
80
80
95
dB
80
IDD Supply current
VO = 2.5 V, No load
25°C
Full range
80 125
150
80 125
µA
150
â Full range is â40°C to 125°C for Q suffix.
NOTE 4: Typical values are based on the input offset voltage shift observed through 500 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265