Operating Characteristics
VDD = 5 V (unless otherwise noted)
PARAMETER
SR+
Positive slew rate at unity
gain
TEST CONDITIONS
VO(PP) = 0.8 V, CL = 50 pF, RL = 10 kΩ
TJ (1)
25°C
Full range
MIN
TYP
MAX UNIT
10
16
9
V/μs
SR–
Negative slew rate at unity
gain
25°C
VO(PP) = 0.8 V, CL = 50 pF, RL = 10 kΩ Full range
11
19
8.5
V/μs
Vn
Equivalent input noise
voltage
f = 100 Hz
f = 1 kHz
25°C
12
nV/√Hz
8.5
In
THD+N
t(on)
t(off)
ts
Equivalent input noise current f = 1 kHz
Total harmonic distortion plus
noise
VO(PP) = 3 V,
RL = 10 kΩ and 250 Ω,
f = 1 kHz
Amplifier turn-on time(2)
Amplifier turn-off time(2)
Gain-bandwidth product
Settling time
RL = 10 kΩ
RL = 10 kΩ
f = 10 kHz, RL = 10 kΩ
V(STEP)PP = 1 V, AV = –1,
CL = 10 pF, RL = 10 kΩ
V(STEP)PP = 1 V, AV = –1,
CL = 47 pF, RL = 10 kΩ
AV = 1
AV = 10
AV = 100
0.1%
0.01%
0.1%
0.01%
25°C
25°C
25°C
25°C
25°C
25°C
0.6
0.002
0.012
0.085
0.15
1.3
10
0.18
0.39
0.18
0.39
fA/√Hz
%
μs
μs
MHz
μs
φm
Phase margin
Gain margin
RL = 10 kΩ
RL = 10 kΩ
CL = 50 pF
CL = 0 pF
CL = 50 pF
CL = 0 pF
25°C
25°C
32
deg
40
2.2
dB
3.3
(1) Full range is –40°C to 125°C.
(2) Disable time and enable time are defined as the interval between application of the logic signal to SHDN and the point at which the
supply current has reached half its final value.
6