English
Language : 

OPA376-Q1_16 Datasheet, PDF (6/34 Pages) Texas Instruments – Low-Noise, Low Quiescent Current, Precision Operational Amplifier
OPA376-Q1, OPA2376-Q1, OPA4376-Q1
SBOS549A – APRIL 2011 – REVISED JANUARY 2016
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
Voltage
Current
Temperature
Supply voltage, VS = (V+) – (V–)
Signal input pin(2)
Signal input pin(2)
Output short-circuit(3)
Operating, TA
Junction, TJ
Storage, Tstg
MIN
(V–) – 0.5
–40
–65
MAX
7
(V+) + 0.5
±10
Continuous
125
150
150
UNIT
V
V
mA
°C
°C
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Input terminals are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5 V beyond the supply rails should
be current limited to 10mA or less.
(3) Short-circuit to ground, one amplifier per package.
6.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per AEC Q100-002(1)
Charged-device model (CDM), per AEC Q100-011
VALUE
±XXX
±1000
(1) AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
UNIT
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
Supply voltage, VS = (V+) – (V–)
TA
Operating temperature
MIN
2.2 (±1.1)
–40
NOM
MAX
5.5 (±2.75)
150
UNIT
V
°C
6
Submit Documentation Feedback
Copyright © 2011–2016, Texas Instruments Incorporated
Product Folder Links: OPA376-Q1 OPA2376-Q1 OPA4376-Q1