English
Language : 

LT1014_17 Datasheet, PDF (6/35 Pages) Texas Instruments – QUAD PRECISION OPERATIONAL AMPLIFIERS
LT1014, LT1014A, LT1014D
QUAD PRECISION OPERATIONAL AMPLIFIERS
SLOS039D − JULY 1989 − REVISED AUGUST 2009
electrical characteristics at specified free-air temperature, VCC± = 5 V, VCC− = 0, VO = 1.4 V, VIC = 0
(unless otherwise noted)
PARAMETER
VIO
Input offset voltage
IIO
Input offset current
IIB
Input bias current
VICR
Common-mode
input voltage range
VOM
Maximum peak output
voltage swing
AVD
Large-signal differential
voltage amplification
ICC
Supply current
per amplifier
† Full range is 0°C to 70°C.
TEST CONDITIONS
RS = 50 Ω
Output low, No load
Output low,
RL = 600 Ω to GND
Output low, Isink = 1 mA
Output high, No load
Output high,
RL = 600 Ω to GND
VO = 5 mV to 4 V,
RL = 500 Ω
TA†
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
Full range
25°C
25°C
25°C
Full range
LT1014C
MIN TYP MAX
90 450
570
0.2
2
6
−15 −50
−90
0 −0.3
to 3.5 to 3.8
0 to 3
15
25
5
10
13
220 350
4 4.4
3.4
4
3.2
LT1014D
MIN TYP MAX
250 950
1200
0.2
2
6
−15 −50
−90
0 −0.3
to 3.5 to 3.8
0 to 3
15
25
5
10
13
220 350
4 4.4
3.4
4
3.2
25°C
1
1
25°C
Full range
0.3 0.5
0.55
0.3 0.5
0.55
UNIT
µV
nA
nA
V
mV
V
V/µV
mA
operating characteristics, VCC± = ±15 V, VIC = 0, TA = 25°C
PARAMETER
TEST CONDITIONS
SR
Slew rate
Vn
Equivalent input noise voltage
f = 10 Hz
f = 1 kHz
VN(PP)
In
Peak-to-peak equivalent input noise voltage
Equivalent input noise current
f = 0.1 Hz to 10 Hz
f = 10 Hz
MIN TYP MAX UNIT
0.2 0.4
V/µs
24
nV/√Hz
22
0.55
µV
0.07
pA/√Hz
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265