LT1014, LT1014A, LT1014D
QUAD PRECISION OPERATIONAL AMPLIFIERS
SLOS039D − JULY 1989 − REVISED AUGUST 2009
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage (see Note 1): VCC+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 V
VCC− . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −22 V
Differential input voltage (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±30 V
Input voltage range, VI (any input) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC− − 5 V to VCC+
Duration of short-circuit current at (or below) TA = 25°C (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . Unlimited
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: LT1014C, LT1014D . . . . . . . . . . . . . . . . . . . . . . . . . . . −0°C to 70°C
LT1014I, LT1014DI . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 105°C
LT1014M, LT1014AM, LT1014DM . . . . . . . . . . . . . −55°C to 125°C
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC−.
2. Differential voltages are at the noninverting input with respect to the inverting input.
3. The output may be shorted to either supply.
PACKAGE
DW
FK
J
N
TA ≤ 25°C
POWER RATING
1025 mV
1375 mV
1375 mV
1150 mV
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25°C
8.2 mW/°C
TA = 70°C
POWER RATING
656 mW
11.0 mW/°C
880 mW
11.0 mW/°C
880 mW
9.2 mW/°C
736 mW
TA = 105°C
POWER RATING
369 mW
495 mW
495 mW
414 mW
TA = 125°C
POWER RATING
205 mW
275 mW
275 mW
230 mW
4