English
Language : 

BQ27520-G2 Datasheet, PDF (6/47 Pages) Texas Instruments – System-Side Impedance Track™ Fuel Gauge With Integrated LDO
bq27520-G2
SLUSAB7A – MARCH 2011 – REVISED AUGUST 2011
3.3 POWER-ON RESET
TA = –40°C to 85°C, typical values at TA = 25°C and VREGIN = 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
VIT+
VHYS
Positive-going battery voltage input at VCC
Power-on reset hysteresis
2.09
45
www.ti.com
TYP MAX UNIT
2.20 2.31 V
115
185 mV
3.4 2.5V LDO REGULATOR
TA = 25°C, CLDO25 = 1μF, VREGIN = 3.6V (unless otherwise noted)
PARAMETER
TEST CONDITION
2.5 V LDO REGULATOR(1)
VREG25
VIH(CE)
VIL(CE)
Regulator output voltage
CE High-level input
voltage
CE Low-level input
voltage
2.7V ≤ VREGIN ≤ 4.5V, IOUT ≤ 16mA
2.45V ≤ VREGIN < 2.7V (low battery),
IOUT ≤ 3mA
VREGIN = 2.7 to 4.5V
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
VDO
ΔVREGTEMP
Regulator dropout voltage
Regulator output change
with temperature
2.7V, IOUT ≤ 16mA
2.45V, IOUT ≤ 3mA
VREGIN = 3.6V, IOUT = 16mA
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
ΔVREGLINE
ΔVREGLOAD
ISHORT (2)
Line regulation
Load regulation
Short circuit current limit
2.7V ≤ VREGIN ≤ 4.5V, IOUT = 16mA
0.2mA ≤ IOUT ≤ 3mA, VREGIN = 2.45 V
3mA ≤ IOUT ≤ 16mA, VREGIN = 2.7 V
VREG25 = 0V
TA = –40°C to 85°C
(1) LDO output current, IOUT, is the sum of internal and external load currents.
(2) Assured by design. Not production tested.
MIN NOM MAX UNIT
2.4 2.5 2.54 V
2.4
V
2.65
0.5%
18
34
31
V
0.8
325
mV
50
40 mV
40
mV
250 mA
3.5 INTERNAL TEMPERATURE SENSOR CHARACTERISTICS
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
GTEMP
Temperature sensor voltage gain
–2
UNIT
mV/°C
3.6 HIGH-FREQUENCY OSCILLATOR
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
UNIT
fOSC
fEIO
tSXO
Operating frequency
Frequency error(1) (2)
Start-up time(3)
TA = 0°C to 60°C
TA = –20°C to 70°C
TA = –40°C to 85°C
–2%
–3%
–4.5%
2.097
0.38%
0.38%
0.38%
2.5
2%
3%
4.5%
5
MHz
ms
(1) The frequency error is measured from 2.097 MHz.
(2) The frequency drift is included and measured from the trimmed frequency at VCC = 2.5 V, TA = 25°C.
(3) The start-up time is defined as the time it takes for the oscillator output frequency to be within ±3% of typical oscillator frequency.
6
ELECTRICAL SPECIFICATIONS
Submit Documentation Feedback
Product Folder Link(s) :bq27520-G2
Copyright © 2011, Texas Instruments Incorporated