English
Language : 

MSP430F2619S-HT_14 Datasheet, PDF (52/93 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F2619S-HT
SLAS697D – MARCH 2010 – REVISED OCTOBER 2013
www.ti.com
USCI (SPI Slave Mode) – Electrical Characteristics
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)(1) (see Figure 30
and Figure 31)
tSTE,LEAD
PARAMETER
STE lead time,
STE low to clock
TEST CONDITIONS
VCC
2.2 V/3 V
MIN TYP MAX UNIT
50
ns
tSTE,LAG
STE lag time,
Last clock to STE high
2.2 V/3 V
10
ns
tSTE,ACC
STE access time,
STE low to SOMI data out
2.2 V/3 V
50
ns
tSTE,DIS
STE disable time,
STE high to SOMI high
impedance
2.2 V/3 V
50
ns
tSU,SI
SIMO input data setup time
2.2 V
20
ns
3V
15
tHD,SI
SIMO input data hold time
2.2 V
10
ns
3V
10
tVALID,SO
SOMI output data valid time
UCLK edge to SOMI valid,
CL = 20 pF
2.2 V
3V
75 110
ns
50
75
(1) fUCxCLK = 1/2tLO/HI with tLO/HI ≥ max(tVALID,MO(USCI) + tSU,SI(Slave), tSU,MI(USCI) + tVALID,SO(Slave)).
For the slave parameters tSU,SI(Slave) and tVALID,SO(Slave), see the SPI parameters of the attached slave.
1/fUCxCLK
UCLK
CKPL = 0
CKPL = 1
tLOW/HIGH tLOW/HIGH
tSU,MI
tHD,MI
SCMI
SIMO
tVALID, MO
Figure 28. SPI Master Mode, CKPH = 0
52
Submit Documentation Feedback
Copyright © 2010–2013, Texas Instruments Incorporated
Product Folder Links: MSP430F2619S-HT