English
Language : 

TLE2082AIDR Datasheet, PDF (51/79 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED JFET-INPUT OPERATIONAL AMPLIFIERS
TLE208x, TLE208xA, TLE208xY
EXCALIBUR HIGH-SPEED JFET-INPUT
OPERATIONAL AMPLIFIERS
SLOS182B – FEBRUARY 1997 – REVISED JUNE 2001
TYPICAL CHARACTERISTICS†
MAXIMUM PEAK OUTPUT VOLTAGE
vs
FREE-AIR TEMPERATURE
5
IO = – 200 µA
4
IO = – 2 mA
3
2
IO = – 20 mA
1
0 VCC ± = ± 5 V
–1
–2
IO = 20 mA
–3
IO = 2 mA
–4
–5
IO = 200 µA
– 75 – 55 – 35 –15 5 25 45 65 85 105 125
TA – Free-Air Temperature – °C
Figure 24
MAXIMUM PEAK OUTPUT VOLTAGE
vs
FREE-AIR TEMPERATURE
15
IO = – 200 µA
IO = 200 µA
14.5
14
13.5
IO = 2 mA
IO = – 2 mA
13
IO = 20 mA
12.5
12
IO = – 20 mA
11.5
11
10.5 VCC ± = ± 15 V
10
– 75 – 55 – 35 –15 5 25 45 65 85 105 125
TA – Free-Air Temperature – °C
Figure 25
MAXIMUM PEAK OUTPUT VOLTAGE
vs
SUPPLY VOLTAGE
25
TA = 25°C
20
IO = – 200 µA
15
10
IO = – 2 mA
5
IO = – 20 mA
0
–5
IO = 20 mA
–10
–15
IO = 200 µA
– 20
IO = 2 mA
– 25
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25
|VCC ± | – Supply Voltage – V
Figure 26
MAXIMUM PEAK-TO-PEAK OUTPUT VOLTAGE
vs
FREQUENCY
30
VCC ± = ± 15 V
25
TA = 25°C,
125°C
RL = 2 kΩ
20
TA = – 55°C
15
TA = 25°C,
125°C
10 VCC ± = ± 5 V
5
0
100 k
TA = – 55°C
1M
f – Frequency – Hz
Figure 27
10 M
† Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
51