English
Language : 

TLC5923_16 Datasheet, PDF (5/28 Pages) Texas Instruments – 16-CHANNEL LED DRIVER WITH DOT CORRECTION
TLC5923
www.ti.com
SLVS550B – DECEMBER 2004 – REVISED JANUARY 2013
NAME
BLANK
GND
IREF
MODE
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
OUT9
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
PGND
SCLK
SIN
SOUT
VCC
XERR
XLAT
TERMINAL
NO.
TSSOP
QFN
2
30
1
29
31
27
30
26
7
8
10
11
12
13
15
16
17
18
20
21
22
23
25
26
6, 9, 14,
19, 24, 27
3
4
6
7
8
9
11
12
13
14
16
17
18
19
21
22
2, 5, 10,
15, 20, 23
4
32
5
1
28
24
32
28
29
25
3
31
Terminal Functions
I/O
DESCRIPTION
I
Blank (Light OFF). When BLANK=H, All OUTn outputs are forced OFF. When BLANK=L,
ON/OFF of OUTn outputs are controlled by input data.
Ground
I/O Reference current terminal
I
Mode select. When MODE=L, SIN, SOUT, SCLK, XLAT are connected to ON/OFF control
logic. When MODE=H, SIN, SOUT, SCLK, XLAT are connected to dot-correction logic.
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
O Constant current output
Power ground
I
Data shift clock. Note that the internal connections are switched by MODE (pin #30). At
SCLK↑, the shift-registers selected by MODE shift the data.
I Data input of serial I/F
O Data output of serial I/F
Power supply voltage
O
Error output. XERR is open drain terminal. XERR transistions from H to L when LOD or TEF
detected.
Data latch signal. When MODE = L (ON/OFF data mode), XLAT is an edge-triggered latch
signal of ON/OFF registers. The serial data in ON/OFF input shift registers is latched into the
I
ON/OFF registers at the rising edge of XLAT. When MODE = H (DC data mode), XLAT is a
level-triggered latch signal of dot correction registers. The serial data in DC input shift
registers is written into dot correction registers when XLAT = H. The data in dot correction
registers is held constant when XLAT = L.
Copyright © 2004–2013, Texas Instruments Incorporated
Product Folder Links: TLC5923
Submit Documentation Feedback
5