English
Language : 

SN74HC4060-Q1 Datasheet, PDF (5/13 Pages) Texas Instruments – 14-STAGE ASYNCHRONOUS BINARY COUNTERS AND OSCILLATORS
SN74HC4060−Q1
14-STAGE ASYNCHRONOUS BINARY COUNTERS AND OSCILLATORS
PARAMETER MEASUREMENT INFORMATION
SCLS726 − DECEMBER 2011
Input
In-Phase
Output
Out-of-Phase
Output
From Output
Under Test
Test
Point
Reference
Input
VCC
50%
CL = 50 pF
(see Note A)
0V
tsu
LOAD CIRCUIT
Data
Input
50%
10%
90%
90%
VCC
50%
10% 0 V
50%
tPLH
50%
tPHL
VCC
tr
tf
VOLTAGE WAVEFORMS
0V
SETUP AND INPUT RISE AND FALL TIMES
50%
10%
tPHL
90%
90%
tr
50%
10%
tf
90%
tPLH
50%
10%
VOH
50%
10%
tf
VOL
90% VOH
VOL
tr
High-Level
Pulse
Low-Level
Pulse
50%
tw
50%
VCC
50%
0V
VCC
50%
0V
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
NOTES: A. CL includes probe and test-fixture capacitance.
B. Phase relationships between waveforms were chosen arbitrarily. All input pulses are supplied by generators having the following
characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 6 ns, tf = 6 ns.
C. For clock inputs, fmax is measured when the input duty cycle is 50%.
D. The outputs are measured one at a time with one input transition per measurement.
E. tPLH and tPHL are the same as tpd.
Figure 1. Load Circuit and Voltage Waveforms
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5