English
Language : 

SN74ALVCHR16601VR Datasheet, PDF (5/14 Pages) Texas Instruments – 18-BIT UNIVERSAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
www.ti.com
SN74ALVCHR16601
18-BIT UNIVERSAL BUS TRANSCEIVER
WITH 3-STATE OUTPUTS
SCES123I – SEPTEMBER 1997 – REVISED SEPTEMBER 2004
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
IOH = -100 µA
IOH = -2 mA
IOH = -4 mA
IOH = -6 mA
TEST CONDITIONS
IOH = -8 mA
IOH = -12 mA
IOL = 100 µA
IOL = 2 mA
IOL = 4 mA
VOL
IOL = 6 mA
II
II(hold)
IOZ (3)
ICC
∆ICC
Ci Control inputs
Cio A or B ports
IOL = 8 mA
IOL = 12 mA
VI = VCC or GND
VI = 0.58 V
VI = 1.07 V
VI = 0.7 V
VI = 1.7 V
VI = 0.8 V
VI = 2 V
VI = 0 to 3.6 V(2)
VO = VCC or GND
VI = VCC or GND,
One input at VCC - 0.6 V,
VI = VCC or GND
VO = VCC or GND
IO = 0
Other inputs at VCC or GND
VCC
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
3V
2.7 V
3V
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
3V
2.7 V
3V
3.6 V
1.65 V
2.3 V
3V
3.6 V
3.6 V
3.6 V
3 V to 3.6 V
3.3 V
3.3 V
MIN TYP(1)
VCC - 0.2
1.2
1.9
1.7
2.4
2
2
25
-25
45
-45
75
-75
4
8
MAX
0.2
0.45
0.4
0.55
0.55
0.6
0.8
±5
±500
±10
40
750
UNIT
V
V
µA
µA
µA
µA
µA
pF
pF
(1) All typical values are at VCC = 3.3 V, TA = 25°C.
(2) This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
(3) For I/O ports, the parameter IOZ includes the input leakage current.
5