English
Language : 

PTB48510_14 Datasheet, PDF (5/18 Pages) Texas Instruments – DUAL COMPLEMENTARY-OUTPUT DC/DC CONVERTER FOR DSL
www.ti.com
Not Recommended for New Designs
PTB48510
PTB48511
SLTS219F – FEBRUARY 2004 – REVISED MARCH 2007
ELECTRICAL CHARACTERISTICS
(Unless otherwise stated, TA = 25°C, VI = 48 V, CI = 0 μF, CO = 0 μF, IO1 = IO2 = 3.25 A maximum)
PARAMETER
TEST CONDITIONS
PTB4851xC
MIN
TYP MAX
PO
IO1 or IO2
IO1 - IO2
Output Power
Output Current
Output Load Imbalance
Total output power from VO1 or VO2
Over VI range, IO1 ≤ 0.1 A or IO2 ≤ 0.1 A
IO1 ≤ 0.1 A or IO2 ≤ 0.1 A
0
66 (1)
0
2.2 (2)
0
1 (3)
VO1 or VO2 Output Voltage
Includes set point, line, load, IO1 - IO2 ≤ 0.1 A,
–40°C ≤ TA ≤ 85°C
14.5(2)
15 15.5(2)
ΔRegtemp Temperature Variation
–40°C ≤ TA ≤ 85°C, IO1 ≤ 0.1 A or IO2 ≤ 0.1 VO1 or VO2
A
±1
ΔRegline
ΔRegload
η
Vr
ttr
ΔVtr
IOtrip
Line Regulation
Load Regulation
Efficiency
VO Ripple (pk-pk)
Transient Response
Over Current Threshold
Short Circuit Current
Over VI range, balanced load
VO1 or VO2
Over IO1 or IO2 range, balanced load
VO1 or VO2
IO1 = IO2
20 MHz bandwidth, CO = 10 μF tantalum capacitor
0.1 A/μs load step, 50% to 75% IO1 or IO2 maximum
VO1 or VO2 overshoot/undershoot
VI = 36 V, reset followed by auto-recovery
Continuous overcurrent trip, IO1 = IO2
IO1(pk) IO2(pk)
Duty
2.45
±0.05
±0.1
90%
50
30
±1
3
4.5
10%
±0.5
±1
100 (4)
3.85
VO1(adj) ,
VO2(adj)
fS
VI on
VI off
VIH
VIL
IIL
II standby
tON
CI
CO
Output Voltage Adjust
Range
VO1 and VO2 adjust simultaneously
Switching Frequency
Under-Voltage Lockout
On/Off Enable (pin 3)
High-level input voltage
Over VI and IO ranges
VI increasing
VI decreasing
Referenced to –VI (pin 4)
Low-level input voltage
Low-level input current
Standby Input Current
Pin 3 open circuit
Start-up Time
IO1 ≤ 1 A or IO2 ≤ 1 A, VO1 or VO2 or rising 0 to 0.95 (typ)
Internal Input Capacitance
External Output
Capacitance
Capacitance from either output to COM (pin 6)
7.2
440
3.6
–0.2
6
0
480 (5)
33
32
16.7
520
75 (6)
0.8
–1
2
12
18
3
3000 (7
)
MTBF
Reliability
Per Telcordia SR-332 50% stress,
TA = 40°C, ground benign
2.8
UNIT
W
A
A
V
%VO
%VO
%VO
mVpp
μs
%VO
A
A
V
kHz
V
V
mA
mA
ms
μF
μF
106 hrs
(1) See Safe Operating Area curves or contact the factory for the appropriate derating.
(2) Under balanced load conditions, load current flowing out of VO1 is balanced to within ±0.1 A of that flowing into VO2.
(3) A load imbalance is the difference in current flowing from VO1 to VO2. The module can operate with a higher imbalance but with reduced
specifications.
(4) Output voltage ripple is measured with a 10-μF tantalum capacitor connected from VO1 (pin 5) or VO2 (pin 8), to COM (pin 6).
(5) This is the free-running frequency. The module can be made to synchronize with the PTB48500 when both modules are used together
in a system.
(6) The On/Off Enable (pin 3) has an internal pull-up and may be controlled with an open-collector (or open-drain) transistor. The input is
diode protected and may be connected to VI. The open-circuit voltage is 5 V maximum. If it is left open circuit the converter operates
when input power is applied.
(7) Electrolytic capacitors with very low equivalent series resistance (ESR) may induce instability when used on the output. Consult the
factory before using capacitors with organic, or polymer-aluminum type electrolytes.
Copyright © 2004–2007, Texas Instruments Incorporated
5