English
Language : 

OPA192-Q1 Datasheet, PDF (5/42 Pages) Texas Instruments – 36-V, Precision, Rail-to-Rail Input/Output, Low-Offset Voltage, Low-Input Bias Current Op Amp With e-trim
www.ti.com
OPA192-Q1, OPA2192-Q1, OPA4192-Q1
SBOS850 – MAY 2017
6 Specifications
6.1 Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
Supply voltage, VS = (V+) – (V–)
Signal input pins
Output short circuit(2)
Latch-up per JESD78D
Temperature
Voltage
Current
Operating range
Junction
Storage, Tstg
Common-mode
Differential
MIN
(V–) – 0.5
–55
–65
MAX
±20
(40, single-supply)
(V+) + 0.5
(V+) – (V–) + 0.2
±10
Continuous
Class 1
150
150
150
UNIT
V
V
mA
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Short-circuit to ground, one amplifier per package.
6.2 ESD Ratings
OPA192-Q1
V(ESD) Electrostatic discharge
OPA2192-Q1
V(ESD) Electrostatic discharge
OPA4192-Q1
V(ESD) Electrostatic discharge
Human body model (HBM), per AEC Q100-002(1)
Charged device model (CDM), per AEC Q100-011
Human body model (HBM), per AEC Q100-002(1)
Charged device model (CDM), per AEC Q100-011
Human body model (HBM), per AEC Q100-002(1)
Charged device model (CDM), per AEC Q100-011
VALUE
±4000
±500
±4000
±500
±4000
±500
(1) AEC Q100-002 indicates HBM stressing is done in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
UNIT
V
V
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
Supply voltage, VS = (V+) – (V–)
Specified temperature
MIN
4.5 (±2.25)
–40
NOM
MAX
36 (±18)
+125
UNIT
V
°C
Copyright © 2017, Texas Instruments Incorporated
Submit Documentation Feedback
5