6.4 Thermal Information
THERMAL METRIC(1)
LP2981-N
DBV (SOT-23)
UNIT
5 PINS
RθJA
RθJC(top)
RθJB
ψJT
ψJB
RθJC(bot)
Junction-to-ambient thermal resistance, High-K
Junction-to-case (top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
Junction-to-case (bottom) thermal resistance
175.7
78.0
30.8
2.8
30.3
N/A
°C/W
°C/W
°C/W
°C/W
°C/W
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
6.5 Electrical Characteristics
Unless otherwise specified: TJ = 25°C, VIN = VO(NOM) + 1 V, IL = 1 mA, COUT = 1 μF, VON/OFF = 2 V.(1)
PARAMETER
TEST CONDITIONS
LP2981AI-XX (2)
MIN TYP MAX
LP2981I-XX (2)
MIN TYP MAX
UNIT
ΔVO
Output voltage
tolerance
ΔVO/ΔVIN
Output voltage line
regulation
VIN – VO Dropout voltage(3)
IGND
Ground pin current
IL = 1 mA
1 mA < IL < 100 mA
1 mA < IL < 100 mA
–40°C ≤ TJ ≤ 125°C
VO(NOM) + 1 V ≤ VIN ≤ 16 V
VO(NOM) + 1 V ≤ VIN ≤ 16 V
–40°C ≤ TJ ≤ 125°C
IL = 0 mA
IL = 0 mA, –40°C ≤ TJ ≤ 125°C
IL = 1 mA
IL = 1 mA, –40°C ≤ TJ ≤ 125°C
IL = 25 mA
IL = 25 mA, –40°C ≤ TJ ≤ 125°C
IL = 100 mA
IL = 100 mA, –40°C ≤ TJ ≤ 125°C
IL = 0 mA
IL = 0 mA, –40°C ≤ TJ ≤ 125°C
IL = 1 mA
IL = 1 mA, –40°C ≤ TJ ≤ 125°C
IL = 25 mA
IL = 25 mA, –40°C ≤ TJ ≤ 125°C
IL = 100 mA
IL = 100 mA, –40°C ≤ TJ ≤ 125°C
VON/OFF < 0.3 V
VON/OFF < 0.15 V
–40°C ≤ TJ ≤ 125°C
−0.75
−1
−2.5
0.007
1
7
70
200
65
80
200
600
0.01
0.05
0.75
1
2.5
0.014
0.032
3
5
10
15
100
150
250
375
95
125
110
170
300
550
800
1500
0.8
2
−1.25
−2
−3.5
0.007
1
7
70
200
65
80
200
600
0.01
0.05
1.25
2 %VNOM
3.5
0.014
%/V
0.032
3
5
10
15
mV
100
150
250
375
95
125
110
170
300
550 μA
800
1500
0.8
2
(1) Minimum and maximum limits are ensured through test, design, or statistical correlation over the junction temperature (TJ) range of
–40°C to 125°C, unless otherwise stated. Typical values represent the most likely parametric norm at TA = 25°C, and are provided for
reference purposes only.
(2) Limits are 100% production tested at 25°C. Limits over the operating temperature range are ensured through correlation using Statistical
Quality Control (SQC) methods. The limits are used to calculate Average Outgoing Quality Level (AOQL).
(3) Dropout voltage is defined as the input to output differential at which the output voltage drops 100 mV below the value measured with a
1-V differential.
Copyright © 2000–2016, Texas Instruments Incorporated