English
Language : 

DS91M124 Datasheet, PDF (5/14 Pages) Texas Instruments – DS91M124 125 MHz 1:4 M-LVDS Repeater with LVCMOS Input
Symbol
Parameter
Conditions
Min Typ Max Units
IA(OFF)
Driver High-Impedance Output Power-Off Current VA = 3.8V, VB = 1.2V
DEn = 0V
0
μA
32
0V ≤ VDD ≤ 1.5V
VA = 0V or 2.4V, VB = 1.2V
DEn = 0V
−20
μA
20
0V ≤ VDD ≤ 1.5V
VA = −1.4V, VB = 1.2V
DEn = 0V
−32
μA
0
0V ≤ VDD ≤ 1.5V
IB(OFF)
Driver High-Impedance Output Power-Off Current VA = 3.8V, VB = 1.2V
DEn = 0V
0
μA
32
0V ≤ VDD ≤ 1.5V
VA = 0V or 2.4V, VB = 1.2V
DEn = 0V
−20
μA
20
0V ≤ VDD ≤ 1.5V
VA = −1.4V, VB = 1.2V
DEn = 0V
−32
μA
0
0V ≤ VDD ≤ 1.5V
IAB(OFF)
Driver High-Impedance Output Power-Off Current
VA = VB, −1.4V ≤ V ≤ 3.8V
(IA(OFF) − IB(OFF))
DEn = 0V
−4
μA
4
0V ≤ VDD ≤ 1.5V
CA
Driver Output Capacitance
7.8
pF
CB
Driver Output Capacitance
CAB
Driver Output Differential Capacitance
VDD = 0V
7.8
pF
3
pF
CA/B
Driver Output Capacitance Balance (CA/CB)
1
ICCL
Loaded Supply Current Enabled
RL = 50Ω (All Outputs)
DI = VDD or GND
DEn = VDD or GND (All
Outputs)
65
75
mA
ICCZ
No Load Supply Current Disabled
DI = VDD or GND,
DEn = GND (All Outputs)
19
24
mA
Note 4: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of device reliability
and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or other conditions beyond those indicated in
the Recommended Operating Conditions is not implied. The Recommended Operating Conditions indicate conditions at which the device is functional and the
device should not be operated beyond such conditions.
Note 5: The Electrical Characteristics tables list guaranteed specifications under the listed Recommended Operating Conditions except as otherwise modified
or specified by the Electrical Characteristics Conditions and/or Notes. Typical specifications are estimations only and are not guaranteed.
Note 6: Current into device pins is defined as positive. Current out of device pins is defined as negative. All voltages are referenced to ground except VOD and
ΔVOD.
Note 7: Typical values represent most likely parametric norms for VDD = +3.3V and TA = +25°C, and at the Recommended Operation Conditions at the time of
product characterization and are not guaranteed.
Note 8: Specification is guaranteed by characterization and is not tested in production.
Note 9: Output short circuit current (IOS) is specified as magnitude only, minus sign indicates direction only.
Note 10: CL includes fixture capacitance and CD includes probe capacitance.
www.national.com
4