English
Language : 

BQ27620-G1 Datasheet, PDF (5/45 Pages) Texas Instruments – System-Side Impedance Track™ Fuel Gauge
bq27620-G1
www.ti.com
3 ELECTRICAL SPECIFICATIONS
SLUSAE3 – OCTOBER 2012
3.1 ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)
PARAMETER
VALUE
UNIT
VREGIN
Regulator input range
–0.3 to 5.5
V
–0.3 to 6.0 (2)
V
VCC
VIOD
VBAT
Supply voltage range
Open-drain I/O pins (SDA, SCL, SOC_INT )
BAT input pin
–0.3 to 2.75
V
–0.3 to 5.5
V
–0.3 to 5.5
V
–0.3 to 6.0 (2)
V
VI
ESD
Input voltage range to all other pins ( BI/TOUT , TS , BAT_GD )
Human-body model (HBM), BAT pin
Human-body model (HBM), all other pins
–0.3 to VCC + 0.3
V
1.5
kV
2
TA
Operating free-air temperature range
TF
Functional temperature range
Tstg
Storage temperature range
–40 to 85
°C
–40 to 100
°C
–65 to 150
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Condition not to exceed 100 hours at 25 °C lifetime.
3.2 RECOMMENDED OPERATING CONDITIONS
TA = -40°C to 85°C, VREGIN = VBAT = 3.6V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VREGIN
Supply voltage
No operating restrictions
No FLASH writes
CREGIN
CLDO25
tPUCD
External input capacitor for internal
LDO between REGIN and VSS
External output capacitor for internal
LDO between VCC and VSS
Power-up communication delay
Nominal capacitor values specified.
Recommend a 5% ceramic X5R type
capacitor located close to the device.
MIN
TYP
MAX UNIT
2.8
4.5
V
2.45
2.8
0.1
μF
0.47
1
μF
250
ms
3.3 SUPPLY CURRENT
TA = 25°C and VREGIN = VBAT = 3.6V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
ICC
Normal operating-mode
current (1)
Fuel gauge in NORMAL mode.
ILOAD > Sleep Current
ISLP
Low-power storage-mode
current (1)
Fuel gauge in SLEEP mode.
ILOAD < Sleep Current
IHIB
Hibernate operating-mode
current (1)
Fuel gauge in HIBERNATE mode.
ILOAD < Hibernate Current
(1) Specified by design. Not production tested.
MIN
TYP
MAX UNIT
118
μA
23
μA
8
μA
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: bq27620-G1
ELECTRICAL SPECIFICATIONS
5