7.6 Insulation Specifications
over operating ambient temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VALUE UNIT
GENERAL
CLR External clearance(1)
CPG External creepage(1)
Shortest pin-to-pin distance through air
Shortest pin-to-pin distance across the package surface
≥9
mm
≥9
mm
DTI Distance through insulation
Minimum internal gap (internal clearance) of the double insulation
(2 × 0.0105 mm)
≥ 0.021
mm
CTI Comparative tracking index
DIN EN 60112 (VDE 0303-11); IEC 60112
≥ 600
V
Material group
According to IEC 60664-1
I
Rated mains voltage ≤ 300 VRMS
I-IV
Overvoltage category per IEC 60664-1 Rated mains voltage ≤ 600 VRMS
I-IV
Rated mains voltage ≤ 1000 VRMS
I-III
DIN V VDE V 0884-11 (VDE V 0884-11): 2017-01(2)
VIORM
Maximum repetitive peak isolation
voltage
At ac voltage (bipolar)
2121
VPK
VIOWM
VIOTM
VIOSM
qpd
CIO
RIO
Maximum-rated isolation working
voltage
Maximum transient isolation voltage
Maximum surge isolation voltage(3)
Apparent charge(4)
Barrier capacitance, input to output(5)
Insulation resistance, input to output(5)
Pollution degree
At ac voltage (sine wave)
At dc voltage
VTEST = VIOTM, t = 60 s (qualification test)
VTEST = 1.2 × VIOTM, t = 1 s (100% production test)
Test method per IEC 60065, 1.2/50-μs waveform,
VTEST = 1.6 × VIOSM = 12800 VPK (qualification)
Method a, after input/output safety test subgroup 2/3,
Vini = VIOTM, tini = 60 s,
Vpd(m) = 1.2 × VIORM = 2545 VPK, tm = 10 s
Method a, after environmental tests subgroup 1,
Vini = VIOTM, tini = 60 s,
Vpd(m) = 1.6 × VIORM = 3394 VPK, tm = 10 s
Method b1, at routine test (100% production) and preconditioning
(type test), Vini = VIOTM, tini = 1 s,
Vpd(m) = 1.875 × VIORM = 3977 VPK, tm = 1 s
VIO = 0.5 VPP at 1 MHz
VIO = 500 V at TA = 25°C
VIO = 500 V at 100°C ≤ TA ≤ 125°C
VIO = 500 V at TS = 150°C
1500
2121
7000
8400
8000
≤5
VRMS
VDC
VPK
VPK
≤5
pC
≤5
~1
pF
> 1012
> 1011
Ω
> 109
2
Climatic category
40/125/21
UL1577
VISO Withstand isolation voltage
VTEST = VISO = 5000 VRMS or 7000 VDC, t = 60 s (qualification),
VTEST = 1.2 × VISO = 6000 VRMS, t = 1 s (100% production test)
5000
VRMS
(1) Apply creepage and clearance requirements according to the specific equipment isolation standards of an application. Care must be
taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on the printed
circuit board (PCB) do not reduce this distance. Creepage and clearance on a PCB become equal in certain cases. Techniques such as
inserting grooves and ribs on the PCB are used to help increase these specifications.
(2) This coupler is suitable for safe electrical insulation only within the safety ratings. Compliance with the safety ratings shall be ensured by
means of suitable protective circuits.
(3) Testing is carried out in air or oil to determine the intrinsic surge immunity of the isolation barrier.
(4) Apparent charge is electrical discharge caused by a partial discharge (pd).
(5) All pins on each side of the barrier are tied together, creating a two-pin device.
Copyright © 2017, Texas Instruments Incorporated