ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted) (1)
VCC
Supply voltage range(2)
VO
Output voltage range (all terminals)
VI
Input voltage range (all terminals)
Continuous total power dissipation
Tstg
Storage temperature range
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
VALUE
–0.5 to 4
–0.5 to VCC + 0.5
–0.5 to 5.5
See Dissipation Rating Table
–6 to 150
260
UNIT
V
V
°C
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to the GND terminals.
PACKAGE
DGG
DISSIPATION RATINGS
TA ≤ 25°C
POWER RATING
1316 mW
DERATING FACTOR(1)
ABOVE TA = 25°C
13.1 mW/°C
TA = 70°C
POWER RATING
726 mW
(1) This is the inverse of the junction-to-ambient thermal resistance when board mounted and with no air
flow.
RECOMMENDED OPERATING CONDITIONS
VCC
Supply voltage
VIH
High-level input voltage
VIL
Low-level input voltage
ZL
Differential load impedance
TA
Operating free-air temperature
MIN NOM MAX UNIT
3
3.3 3.6 V
2
V
0.8 V
90
132 Ω
0
70 °C
TIMING REQUIREMENTS
PARAMETER
tc
Input clock period
tw Pulse duration, high-level input clock
tt
Transition time, input signal
tsu Setup time, data, D0–D27 valid before CLKIN↓ (See Figure 2)
th Hold time, data, D0–D27 valid after CLKIN↓ (See Figure 2)
MIN
14.7
0.4 tc
3
1.5
TYP MAX UNIT
32.4 ns
0.6 tc ns
5 ns
ns
ns
4
Submit Documentation Feedback